Back to search

Freie Universität Berlin

Clinical analysis and preoperative predictors of survival in children after ventricular assist device implantation

Abstract

dc:description.abstract

Background: To assist the failing heart in infants and small children, mechanical circulatory support with a variety of devices has been routinely applied in pediatric patients with end-stage heart disease, aiming at bridge to transplantation or myocardial recovery. Although extracorporeal membrane oxygenation (ECMO) and centrifugal pumps have been widely and successfully used since the development of pediatric cardiac surgery, their applications are largely limited by the short-term support and immobilization of the patient. Several adult-sized ventricular assist devices (VADs) could be implanted in larger adolescent patients, but they could not provide circulatory support in small children with weight less than 20 kg. Current experience with the use of pediatric-specific VADs in children is limited, and previous studies were mostly based on either adult-sized VADs or relatively small patient numbers. We describe our recent 10-year experience with long- term mechanical circulatory support in small children and young adolescents with intractable heart failure, using Berlin Heart EXCOR Pediatric VAD (Berlin Heart AG, Berlin, Germany), which is designed specifically for all age groups of the pediatric population, and further define the potential risk factors for postimplantation mortality in children. Methods: Between 01/1999 Jan and 12/2009 Dec, 73 children were implanted with the Berlin Heart EXCOR pediatric ventricular assist device at the Deutsches Herzzentrum Berlin. We conducted a retrospective, non-randomized study by obtaining patient data from the ventricular assist device registry database of our institution. The following clinical data were collected and analyzed: (1) patient characteristics: age, sex, body surface area, body length, weight, body mass index, temperature, pulse oxygen saturation, causes of heart failure, prior sternotomy, history of comorbidities, VAD type, year of implantation; (2) medical and device therapy for heart failure: preimplantation cardiac pulmonary resuscitation, intravenous inotropes, vasopressor, vasodilators, diuretics, antiarrhythmic therapy, other mechanical circulatory support before EXCOR implantation; (3) measures of hemodynamic severity of heart failure: LVEF, blood pressure (systolic, diastolic, mean), heart rate, rhythm, pulse oxygen saturation, central venous pressure, pulmonary artery pressure (systolic, diastolic, mean), pulmonary capillary wedge pressure, cardiac output and index; (4) laboratory data (< 24 hours before VAD implantation): serum sodium concentration, serum potassium concentration, serum glucose concentration, hemoglobin, white blood count, hematocrit, platelet count, international normalization ratio, partial thromboplastin time, alanine and aspartate aminotransferase activity, lactate dehydrogenase, creatine kinase-MB, γ-glutamyl transpeptadase, total bilirubin concentration, albumin concentration, total protein, blood urea nitrogen, serum creatinine concentration, serum C-reactive protein; (5) clinical outcomes: duration of ventilation, period of ICU stay, duration of EXCOR support, causes of EXCOR explantation, cause of death, posttransplantation survival, and adverse events. Results: The etiology of end-stage myocardial failure included non- congenital (72%) and congenital heart disease (27%); the median age at implantation was 4 years (12 days to 17 years), and the median support time was 59 days (1 to 432 days). Thirty-three patients were bridged to heart transplantation, 14 were explanted following myocardial recovery, 2 continued to receive support, and the other 24 died on support. The accurate rate of survival at 30 days and 1 year after EXCOR implantation was 80.3% and 55.5%, respectively. For the subset of 56 children listed for transplantation, 77% survived during the support period. No differences in clinical outcomes between small children with BSA < 1.2 m2 and larger children were observed, except that there was a higher incidence of stroke in small recipients. Patients supported with a biventricular assist device had significantly higher postimplantation mortality as compared to children with UniVAD. Lower postimplantation survival was also observed in patients with congenital cardiac disease compared with children with a non-congenital diagnosis. Our multivariate analysis revealed that congenital diagnosis and CVP > 17 mmHg were independent risk factors for survival after EXCOR implantation. For patients without any of these factors, the 30-day and 1-year survival after EXCOR implantation was 92.2%±4.4% and 75.9%±8.3%; for the combined group with at least 1 risk factor, it was 75.9%±8.3% and 29.7%±10.4%, respectively. Conclusions: (1) The Berlin Heart EXCOR pediatric VAD provides efficient and reliable mechanical circulatory support in both small children and larger adolescents suffered from end-stage heart disease, with encouraging clinical outcomes comparable to those in adult VAD patients; (2) UniVAD recipients had significantly better survival, as compared with patients supported with BiVAD. The overall survival to transplantation, recovery of ventricular function, or ongoing device support for patients with congenital heart disease were also significantly lower than in children with a non-congenital diagnosis; (3) Incidences of certain complications (such as cerebralvascular accident) in our study remained high (especially in small pediatric patients), which might emphasize the need of further improvement in anticoagulation therapy for children after VAD implantation; (4) The presence of congenital heart disease and CVP > 17 mmHg were independent risk factors for postimplantation survival of children supported with EXCOR VAD. Further analysis demonstrated that the high-risk patient group was associated with significantly elevated mortality as compared to those recipients without any risk factor. (5) Of note, age- dependent factors were not correlated with different patient survival outcomes after implantation, even in our initial univariate analysis, which supported our point that EXCOR can provide satisfactory support and has comparable clinical outcomes in both small children and larger adolescent patients.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fan, Ye
Committee members dc:contributor.committeemember
  • Prof. Dr. med. Johannes Albes
  • Prof. Dr. med. Hermann Eichstädt
  • Dr. med. Rufus Baretti

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000024633-9
Dc Identifier Other
FUDISS_thesis_000000024633
FUDISS_derivate_000000009861

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Fan, Ye. Clinical analysis and preoperative predictors of survival in children after ventricular assist device implantation. 2011. https://refubium.fu-berlin.de/handle/fub188/12697