Freie Universität Berlin
The clinical retrospective analysis of fixed and removable implant-supported prostheses in edentulous patients-a 10-year study
Abstract
dc:description.abstractVarious prosthetic design variables must be considered for dentists or patients when implant prosthodontic treatment is indicated for the completely edentulous jaw. One of the most fundamental of these is the selection of a fixed versus removable type. The outcome of oral implant treatment for edentulous jaw has been reported in numerous publications. Of these studies only few compared the two different modes of implant-retained superstructures. The results are controversial. Some studies found that the oral implant outcomes were differentiated by jaw (maxilla or mandible), by gender, by kind of implant system or by type of prosthetic design (fixed or removable prostheses), some found no relation with any of the above factors. There remains little conclusive evidence to guide clinicians or patients as to the optimal type of prosthesis for rehabilitation of the fully edentulous maxilla or mandible. Chart reviews of 227 completely edentulous patients with 1652 implants were performed with a total of 308 prostheses (25 % fixed/ 75 % removable). Sixty patients with 15 fixed and 45 removable implant-retained restorations in the maxilla and 86 patients with 7 fixed and 79 removable implant-retained prostheses in the mandible were evaluated. Eighty-one patients were rehabilitated in both jaws with 162 prostheses. There were two types of retaining methods for removable dentures, 98.7 % were bar-retained and 1.3 % telescope-retained and usually supported by 6 maxillary implants or 4 implants in the mandible. Of 76 fixed prostheses, 24 (31.58%) were cement- retained and 52 were screw-retained prostheses (68.42%). The fixed implant- retained prostheses were usually supported by 6-8 implants and 5-6 implants in the maxilla and mandible, respectively. Seven implant systems were utilized: Camlog (55.08%), NobelBiocare (Steri-Oss 21.37%, Branemark 11.99%, Replace 2.60%, Zygoma implants 0.06%), Straumann (7.63%) and IMZ (1.27%). The cumulative implant survival rate, with a mean observation period of 4.3 years, was 94.76% for all implants. Among 73 lost implants, 34 were lost in the maxilla and 39 in the mandible, the cumulative implant survival rate was 94.87% and 94.53% respectively. As to 73 lost implants in gender, 27 were lost in males and and 46 were lost in females, the cumulative implant survival rate was 95.93% and 93.93% respectively. There was no significant difference in cumulative implant survival rate between maxilla and mandible, or between male and female. There was also no significant difference between the implant systems used. A significant difference between the survival of fixed (98.02%) and removable (93.55%) prostheses was seen. This retrospective study confirms good clinical outcome of implant-supported treatment concepts for the rehabilitation of totally edentulous patients in a medium-term perspective, and suggests that the implant survival rate is not correlated with gender and implant location or the use of different implant systems. The type of prostheses is correlated with the survival rate. Implant-supported fixed prostheses seem to have a better prognosis than removable prostheses. Future research should be focused on long-term evaluation of the restoration in function-monitoring maintenance parameters.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2008
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Xiang, Lixin
- Committee members dc:contributor.committeemember
-
- Prof. Dr. Dr. B. Hoffmeister
- Prof. Dr. Dr. W. Wagner
- Prof. Dr. A. M. Kielbassa
Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-fudissthesis000000006355-8
- Identifier URI
- http://dx.doi.org/10.17169/refubium-17837
- Dc Identifier Other
-
FUDISS_thesis_000000006355
FUDISS_derivate_000000004751