Back to search

Freie Universität Berlin

Demineralisation des Bracketumfeldes nach Anwendung konventioneller und selbstkonditionierender Schmelzadhäsivsysteme

Abstract

dc:description.abstract

Every treatment with fixed orthodontic appliances bears the risk of developing white spots adjacent to the bracket. The aim of this in-situ-study was to determine the mineral loss after using two self-etching primers and compare it to the traditional acid-etch technique. Since the wearing period of fixed appliances is a decisive factor for the development of enamel lesions, it was analyzed in a systematic review, if piezosurgical procedures or osteoperforation could accelerate orthodontic tooth movement. 15 probands wore a removable orthodontic appliance for 28 days. In this appliance enamel specimens from extracted third molars were embedded. Two self-etching primers and a conventional acid-etch technique were used to fix brackets. On each side, one untreated specimen was integrated, which served as a control group. Mineral loss expressed in percentage fluorescence loss (ΔF in %) was assessed quantitatively with light-induced fluorescence (Inspektor Pro Intraoral Fluorescence Camera, Inspektor Research Systems BV). Furthermore the surface roughness (Sa-value in nm) was evaluated by means of a 3D scanning microscope (Focus variation scanning microscope, Alicona Imaging). The baseline measurement (T0) was taken after fixing the brackets and before the appliance was incorporated. Further measurements were taken after 3 (T1), 7 (T2), 14 (T3) and 28 (T4) days. The loss of fluorescence and the Sa-values of all used bonding agents were quantitatively compared. The literature search in the databases Pubmed and Google Scholar was performed until May 2016 with the key words “piezo*” AND “tooth movement”, “osteoperforation” and “piezopuncture”. Inclusion criteria were a restriction on human species and a transmucosally surgical procedure without elevation of a mucoperiosteal flap. The investigation using light induced fluorescence revealed for all three bonding agents a decrease of fluorescence loss, thus they received a remineralization. The greatest remineralization was detected for the self-etching system Transbond™ Plus. There were no significant differences between the three groups. Only at the final measurement after four weeks the specimens which were prepared with Transbond™ Plus showed significant lower values for fluorescence loss than the specimens which were prepared with conventional acid-etch technique. The untreated specimens revealed increasing ΔF-values during the whole observation period. The literature search delivered 576 references. Only 13 publications fulfilled the inclusion criteria, 12 of them reported on piezosurgical corticocision and one on osteoperforation. Nine articles represented case series and only four were clinical trials. The reported acceleration in the four trials was inconsistent and in one article it disappeared when assessing the entire treatment. There was no difference in demineralization by using the self-etching primer and the conventional acid-etch technique. An evidence-based statement about the impact of minimally invasive methods on the tooth movement is at present not possible.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Visel, Dominik Dietrich
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-22882-6

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Visel, Dominik Dietrich. Demineralisation des Bracketumfeldes nach Anwendung konventioneller und selbstkonditionierender Schmelzadhäsivsysteme. 2018. https://refubium.fu-berlin.de/handle/fub188/22882