Freie Universität Berlin
Analyse der Sensitivität und Spezifität einer kommerziellen und zweier in-house Taqman Real-time-multiplex-PCR-Assays zur Diagnose von enteropathogenen, enterotoxischen und enteroaggregativen Escherichia coli ohne Verwendung eines Goldstandards
Abstract
dc:description.abstractDiagnostic methods provide the basis for clinical and epidemiological trials. However, the interpretation of results determined by diagnostic methods requires knowledge of the characteristics and limitations of each method. Statistical methods for the estimation of prevalence and treatment efficacy allow adjusting for the diagnostic quality of positivity rates obtained by diagnostic methods, but only under consideration of their sensitivities and specificities. However, especially the diagnostic quality of laboratory diagnostic methods is often insufficiently evaluated and may vary between different laboratories and target populations. Furthermore, data collected from larger representative populations from (sub)tropical regions are often determined by the use of less expensive in-house methods instead of standardised commercial assays because of their high costs. In this study, three multiplex PCRs have been evaluated for the detection of entero-pathogenic (EPEC), entero-toxigenic (ETEC) and entero-aggregative (EAEC) Escherichia coli. 580 stool samples of patients returning from areas of high endemicity were divided into a group of i. short-term (returning travellers) and ii. long-term stay (arriving refugees/locals) and examined by one commercial and two in-house multiplex PCRs. The diagnostic characteristics of an already established in-house PCR and the commercial PCR were estimated using the method of Hui and Walter. The advantage of this method is that no gold standard and therefore no knowledge about the actual status of a potential disease are required for the analysis. Subsequently, the sensitivity and specificity of a newly developed in-house PCR was determined applying the method of Gart and Buck, using the previously mentioned PCRs as a reference. For the detection of EPEC, ETEC and EAEC, the commercial PCR had a sensitivity of 0.84, 0.83 and 0.69, and a specificity of 0.97, 1 and 1, respectively. The yet established in-house PCR had a sensitivity of 0.89, 0.76 and 0.54 and a specificity of 1 for all pathogens. The newly developed PCR presented with a sensitivity of 0.96, 0.61 and 0.69 and a specificity of 0.94, 1, and 1. 3 Though sensitivities of the evaluated PCRs are not high, their use in epidemiological and clinical studies is uncritical, as the methods of Gart and Buck provide target point estimators for the adjustment of sensitivity and specificity of prevalence. However, the lack of sensitivity and the impossibility of adjustment for patient-specific misinterpretations currently diminish their value for clinical diagnosis. Further independent evaluations might help to overcome this limitation.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hahn, Andreas
- Committee members dc:contributor.committeemember
-
- N.N.
- N.N
Subjects
dc:subject × 6Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger, eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-22898-2
- Identifier URI
- http://dx.doi.org/10.17169/refubium-697