Abstract
dc:description.abstractBackground Perioperative bleeding and the subsequent requirements for transfusion are considered to be major risk factors for morbidity and mortality in adult cardiac surgery. The etiology of perioperative bleeding can be difficult to identify and often remains unclear. In order to deliver prompt diagnostics and goal-directed therapy, several point-of-care devices are available. Their use, especially in the frame of transfusion-algorithms, has shown a reduction of blood loss, transfusion requirements, morbidity, mortality and cost. The aim of this study is to confirm the superiority of PoC-based transfusion-algorthims compared to therapy based on standard coagulation parameters in the context of adult cardiac surgery with high risk for perioperative bleeding. Methods In a single-center randomized-controlled trial we included 26 patients undergoing cardiac surgery procedures with a high risk for excessive perioperative bleeding. The management of coagulation-active products except packed red blood cells was based on two newly designed algorithms, one that used conventional coagulation-tests measured a central laboratory, while the other used point-of-care results of Multiplate\textregistered{} and ROTEM\textregistered{}. Primary end point was the cumulative chest tube blood loss in 24 hours postoperatively, secondary end points were the chest tube blood loss over the time course, the use of transfusions or coagulation products and the results of standard coagulation parameters over the time course. Both groups had diagnostics performed at identical time points with equal definitions of bleeding and the same therapeutical options peri- and postoperatively. Blood loss from chest drainage, transfusion requirements and parameters of hemostasis were recorded from the induction of anaesthesia until at least 24 h postoperatively. In all patients, attending physicians were blinded to the results of coagulation-tests irrelevant to the patient's study group's transfusion algorithm. For data analysis, non-parametrical tests for independent samples were used. Results Perioperative chest tube output after 24 h did not differ with a median of 360 ml (interquartile range 299-599 ml) in the conventional group and 380 ml (interquartile range 310-590 ml) in the point-of-care group (p = 0,77, r = 0,0602). Further, there were no differences between the groups in terms of basic patient characteristics, transfusion requirements, coagulation test results or outcome. Conclusion In this trial we could neither show a reduction of perioperative blood loss or transfusion requirements nor differences in coagulation test results comparing two algorithms based on conventional coagulation testing or point-of-care measurements.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Lehmann, Ferdinand
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 6Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-23503-7
- Identifier URI
- http://dx.doi.org/10.17169/refubium-1289