Back to search

Freie Universität Berlin

In vitro performance of the DIAGNOcam for detecting proximal carious lesions adjacent to composite restorations

Abstract

dc:description.abstract

Objectives: To assess the accuracy of near-infrared-light transillumination (DIAGNO) compared to visual-tactile (VT) and radiographic (RA) evaluation of proximal carious lesions adjacent to composite restorations in vitro. Methods: Two hundred extracted posterior permanent human teeth with occluso-proximal composite restorations were allocated to 50 groups of four posterior teeth, and mounted in a pilot-tested diagnostic model in a dummy head. The teeth were independently assessed by two examiners. Transverse microradiography and visual assessment served as reference tests to detect any lesions (prevalence 24%) and cavitated lesions (18%), respectively, adjacent to restorations. Sensitivity, specificity, positive and negative predictive values and the area under the receiver-operating-characteristics curve (AUC) were calculated. Results: To detect any proximal carious lesions adjacent to composite, the mean sensitivity/specificity were 0.63/0.95 for DIAGNO, 0.70/0.88 for RA when lesions radiographically extending into enamel and dentin were considered, 0.26/0.98 for RA when only lesions extending into dentin were considered, and 0.31/0.96 for VT. For cavitated lesions adjacent to proximal composite restorations, these values were RA (enamel and dentin) 0.84/0.88, RA (dentin) 0.34/0.99, DIAGNO 0.69/0.94 and VT 0.40/0.97. AUC did not differ significantly between RA and DIAGNO, while VT showed significantly lower values (p<0.05). Conclusion: Within the limitations of this study, DIAGNO seems useful for detecting proximal carious lesions adjacent to composite restorations. Clinical relevance: Near-infrared-light transillumination could be used as a radiation-free adjunct or alternative to RA for detecting carious lesions adjacent to composite restorations.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Elhennawy, Karim
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger, eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Elhennawy, Karim. In vitro performance of the DIAGNOcam for detecting proximal carious lesions adjacent to composite restorations. 2018. https://doi.org/10.17169/refubium-1315