Back to search

Freie Universität Berlin

Untersuchungen zum AKE mit gerüstfreier Perikardprothese

Abstract

dc:description.abstract

Introduction The Freedom SOLO™ Prosthesis (Livanova Deutschland GmbH, Munich, formerly Sorin Biomedica) is a stentless bovine biological prosthesis, which allows simplified implantation and also shows very good hemodynamic results. This paper investigates the long-term measures of morbidity, lethality and functional results. Methods From January 2005 to December 2009, a total of 282 patients (49.6% female, mean age 74.1±7.2 years) received an isolated (n=135) or combined (n=147) aortic valve replacement with the Freedom SOLOTM prosthesis at the Department for Cardiovascular Surgery of Charité - Universitätsmedizin Berlin. The data was collected from September 2013 to May 2015. The median follow-up time was 5.6 years (1st quartile 2.5 years, 3rd quartile 7.5 years, maximum 10.1 years) and included 1410 patient-years. Results Within 30 days of the procedure, 12 patients died (30-day mortality 4.3%). In the EuroSCORE II classified groups with low (EuroSCORE II <5%, n=162), medium (EuroSCORE II 5-10%, n=65) and high risk (EuroSCORE II> 10%, n=55) the 30-day lethality was 2.5%, 4.6% and 9.1%. Survival after 5 years was 70.8±2.8% overall and in the low, medium and high risk groups 78.7±3.3%, 69.6±6.0% and 50.8±6,7% (log rank p <0.001) respectively. A total of 13 reinterventions were necessary, 5 due to structural degeneration (n=5), 5 due to endocarditis (n=5), and one due to valvular thrombosis (n=1, other reasons unknown). Freedom from reintervention was 96.4±1.3% after 5 years. In 7 patients endocarditis occurred (freedom from endocarditis after 5 years 97.3±1.1%). Cerebrovascular events occurred in 28 patients (freedom from cerebrovascular events after 5 years 90.0±2.0%), other thromboembolic events in 4 patients (freedom from other thrombotic events after 5 years 98.5±0.9%) and bleeding events in 9 patients (freedom from hemorrhagic events after 5 years 97.6±1.1%). Based on the NYHA classification, there was a functional improvement at the follow-up (NYHA ≤II / ≥III 89% / 11% versus 38% / 62% preoperatively, p=0.000). The mean gradients over the valvular prosthesis (9.5±5.9 mmHg postoperative vs. 10.6±6.8 mmHg at follow-up) and the indexed valve opening area (0.9±0.3 cm2/m2 postoperative vs. 0.8±0.3 cm2/m2 at follow-up) remained stable over the long term. Discussion In this single-center long-term study, a low rate of valve-related events and good hemodynamic and functional outcomes could be demonstrated for aortic valve replacement with the stentless Freedom SOLO™ bovine pericardial valve prosthesis. These results ought to be confirmed in larger groups or continued follow-up.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zielinski, Christina Barbara
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Zielinski, Christina Barbara. Untersuchungen zum AKE mit gerüstfreier Perikardprothese. 2019. https://doi.org/10.17169/refubium-2647