Specimen radiography: digital breast tomosynthesis versus full field digital mammography

Abstract

dc:description.abstract

Introduction Radiography of the excised surgical specimen following image-guided wire localization of impalpable breast lesions is now the accepted standard practice to define resection status in breast conserving surgery. However, margin correlation in specimen radiography performed by routine full-field digital mammography (FFDM) with corresponding histopathology is still very disappointing. The present study was performed to evaluate the usability of digital breast tomosynthesis (DBT) in performing specimen radiography and to measure its accuracy in identifying the mammographic appearance and margins status of the operated lesion, compared to FFDM. The histopathology findings were considered to be the gold standard. Patient and methods After ethics-board approval, 102 patients who underwent breast conservative surgery for non-palpable breast lesions were included. All patients underwent ultrasound/mammography guided wire localization of their proven breast carcinoma. After excision, specimens were marked for orientation and imaged using FFDM (2-views) and DBT (1-view). Two blinded readers (R1, R2) retrospectively, reviewed images from both modalities independently. They defined the type of lesions, identified which direction the lesion showed the closest distance to the specimen margin and measured that distance. All results were compared to the final histopathology assessments. Results For FFDM, correct margin direction was identified in 45 cases (44%) by R1 and in 37 cases (36%) by R2. For DBT, 69 cases (68%) were correctly identified by R1 and 70 cases (69%) by R2. The average accuracy was 40% for FFDM and 69% for DBT, the difference was statistically significant (p < 0.0001). For all cases where orientation was correctly detected, FFDM reached an average accuracy of 73% and 77% for DBT in terms of correct margin status detection. The average sensitivity was significantly better for DBT (77%) versus 62% for FFDM. Conclusion DBT showed significant improvement of the accuracy of specimen radiography regarding orientation of the closest margin compared to FFDM and improved sensitivity regarding identification of margin status.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Amer, Heba
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Amer, Heba. Specimen radiography: digital breast tomosynthesis versus full field digital mammography. 2019. https://doi.org/10.17169/refubium-25878