Freie Universität Berlin
Noise reduction and motion elimination in low-dose 4D myocardial computed tomography perfusion (CTP)
Abstract
dc:description.abstractObjectives. To propose and evaluate a four-dimensional (4D) algorithm for joint motion elimination and spatiotemporal noise reduction in low-dose dynamic myocardial computed tomography perfusion (CTP). Methods. Thirty patients with suspected or confirmed coronary artery disease were prospectively included und underwent dynamic contrast-enhanced 320-row CTP. The presented deformable image registration method ASTRA4D identifies a low-dimensional linear model of contrast propagation (by principal component analysis, PCA) of the ex-ante temporally smoothed time-intensity curves (by local polynomial regression). Quantitative (standard deviation, signal-to-noise ratio (SNR), temporal variation, volumetric deformation) and qualitative (motion, contrast, contour sharpness; 1, poor; 5, excellent) measures of CTP quality were assessed for the original and motion-compensated volumes (without and with temporal filtering, PCA/ASTRA4D). Following visual myocardial perfusion deficit detection by two readers, diagnostic accuracy was evaluated using 1.5T magnetic resonance (MR) myocardial perfusion imaging as the reference standard in 15 patients. Results. Registration using ASTRA4D was successful in all 30 patients and resulted in comparison with the benchmark PCA in significantly (p<0.001) reduced noise over time (-83%, 178.5 vs 29.9) and spatially (-34%, 21.4 vs 14.1) as well as improved SNR (+47%, 3.6 vs 5.3) and subjective image quality (motion, contrast, contour sharpness: +1.0, +1.0, +0.5). ASTRA4D resulted in significantly improved per-segment sensitivity of 91% (58/64) and similar specificity of 96% (429/446) compared with PCA (52%, 33/64; 98%, 435/446; p=0.011) and the original sequence (45%, 29/64; 98%, 438/446; p=0.003) in the visual detection of perfusion deficits. Conclusions. The proposed functional approach to temporal denoising and morphologic alignment was shown to improve quality metrics and sensitivity of 4D CTP in the detection of myocardial ischemia.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2019
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Lukas, Steffen
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier URI
- https://refubium.fu-berlin.de/handle/fub188/26159