Back to search

Freie Universität Berlin

Einflüsse auf die invasive Bestimmung des Herzzeitvolumens mittels Thermodilution und indirekter Fick-Methode

Abstract

dc:description.abstract

Introduction: Invasive measurement of cardiac output (CO) is a key hemodynamic parameter. While thermodilution (TD) is considered the method of choice, the calculation of CO based on the Fick principle is often preferred due to reduced cost and time. However, the indirect Fick method (iFM) used in clinical practice relies on an assumed oxygen consumption (VO2). Formulas to predict VO2, such as LaFarge (LaF), Dehmer (De) and Bergstra (Be), have been proposed, all of which were revealed to have limited predictive value in pediatric and adult patients compared to TD. The correlation between the iFM and TD method in an aged, realworld cohort was tested. Furthermore, variables leading to a mismatch between estimated and measured CO were investigated. Methods: A single, clinically-indicated right heart catheterization was performed on each patient with CO estimated by iFM and TD in 194 consecutive patients between April 2015 and August 2017. Six patients were excluded due to incomplete baseline data. The VO2 was assumed by applying the formulas of LaF, De and Be. Body fat estimation was performed with the formula proposed by Jackson and Pollock. Results: We included 188 consecutive patients (70±13 years, 59% male) in the current analysis. Severe tricuspid and mitral regurgitation were present in 25 and 43 patients, respectively. CO-TD exhibited an overall moderate correlation to CO-iFM as assessed by LaF, De and Be formulas with large limits of agreement (-1.22 to 1.62, -2.31 to 1.65, -2.80 to 1.17 l/m², respectively). The mean difference of the CO between methods was 0.40, -0.24 and -0.81 (all p<0.001 for difference to TD), respectively. A rate of error ≥20% occurred with the equations by LaF, De and Be in 32%, 29% and 51% of patients, respectively. TD-method as compared to iFM with LaF formula underestimated CO in patients with severe tricuspid regurgitation (p=0.022) but not when iFM was calculated based on the De (p=0.229) or Be (p=0.418) formula. Body fat estimation (29%± 12%) was performed in a subgroup of patients (n=149). Mitral regurgitation, body fat as well as cardiac rhythm disturbances did not affect the correlation between TD- and iFM. Conclusion: Although CO-eFM exhibits an overall reasonable correlation with CO-TD, the predictive value in a single patient is low. CO-eFM cannot replace CO-TD in elderly patients. Common variables leading to a mismatch between the estimated and the measured CO, such as morbid obesity did not lead to a significant difference in this cohort.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kresoja, Karl-Patrik
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Kresoja, Karl-Patrik. Einflüsse auf die invasive Bestimmung des Herzzeitvolumens mittels Thermodilution und indirekter Fick-Methode. 2019. https://doi.org/10.17169/refubium-25953