Back to search

Freie Universität Berlin

Radiofrequency induced heating for controlled release of a load from thermoresponsive carriers: a 7.0 Tesla Thermal Magnetic Resonance Study

Abstract

dc:description.abstract

Introduction: Temperature is an important attribute of life. Radiofrequency (RF) pulses used for magnetic resonance (MR) spin excitation can be deliberately used to apply a thermal stimulus. Thermal MR integrates this thermal modulation with the imaging capabilities of a MR device providing a tool to study the role of temperature in biological systems, diagnostic contrasts and thermal therapies (e.g. temperature controlled release of a load from thermoresponsive carriers). Thermal MR requires an RF chain that includes dedicated transmit/receive (Tx/Rx) switches that support high peak powers for MR imaging and high average powers for RF heating. Conventional Tx/Rx switches have electronic components in the transmission path limiting the average power handling. In this work, a high power handling Tx/Rx switch design is developed, implemented, and evaluated. This technology was applied in a pilot study in humans and in a feasibility study demonstrating the proof-of-principle of Thermal MR for temperature controlled release of a protein from thermoresponsive nanogels. Methods: In the Tx/Rx switch design, λ/4 stubs were used to route the transmitted RF signal directly to the RF coil/antenna without passing through any electronic components (e.g. PIN diodes). Bench measurements, MR imaging, MR thermometry, and RF heating experiments were performed at f=297MHz (B0=7T) to examine the characteristics and applicability of the switch. Bovine serum albumin (BSA) was loaded to thermoresponsive nanogels (transition temperature = 38°C). As a reference, the release rate was firstly accessed using water bath heating at temperatures: 20°C, 37°C and 43°C. BSA release from the nanogel was subsequently studied using RF heating of Thermal MR at the same temperatures. In this Thermal MR setup one bow tie dipole antenna and a dedicated phantom were used. Results: The proposed design for the Tx/Rx switch provided 35.7dB/41.5dB (Tx/Rx) of isolation and 0.41dB/0.27dB (Tx/Rx) of insertion loss. The switch supported high peak (3.9kW) and high average (120W) RF powers for MRI and RF heating. High-resolution MRI of the wrist yielded image quality competitive with that obtained with a conventional Tx/Rx switch. RF heating in phantom monitored by MR thermometry demonstrated the switch applicability for thermal modulation. The release of BSA from the thermoresponsive nanogels after 6 hours was 12.5% (20°C), 19.5% (37°C) and 32.8% (43°C) in water bath and 12.9% (20°C), 19.6 (37°C) and 29.3% (43°C) with Thermal MR. Conclusion: The high-power Tx/Rx switch enables thermal MR applications at 7.0 Tesla. The reference release profile of the therapeutic load model from the nanocarrier obtained with a water bath setup used for temperature intervention is in accordance with the release kinetics deduced from the thermal MR setup. This finding supports the feasibility of thermal MR for temperature controlled release of a load from thermoresponsive nanocarriers.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ji, Yiyi
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-27798-7

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ji, Yiyi. Radiofrequency induced heating for controlled release of a load from thermoresponsive carriers: a 7.0 Tesla Thermal Magnetic Resonance Study. 2020. https://refubium.fu-berlin.de/handle/fub188/27798