Freie Universität Berlin
Entwicklung der Multi-Kanal-Hochfrequenz Technologie für Natrium und Kalium Magnet-Resonanz-Tomographie bei 7.0 Tesla
Abstract
dc:description.abstractSodium (Na+) and potassium (K+) ions play key roles in the physiology and metabolism of living cells. Primary active transport, which is carried out by sodium/potassium pumps (Na+/K+-ATPase), maintains the ion concentration gradient between intra- and extracellular space. Changes in Na+ and K+ concentration (and distribution) might reflect ongoing pathological processes within a tissue what might be relevant for various types of cardiovascular and ocular disorders. Ultrahigh magnetic resonance imaging (UHF-MRI) provides new opportunities to non-invasively investigate changes in Na+ and K+ concentrations with spatial resolution and within total scan times that are reaching ranges acceptable for clinical applications. Despite an intrinsic to UHF-MRI gain in signal-to-noise ratio (SNR), nuclear magnetic resonance (NMR) signals of sodium (23Na) and potassium (39K) being detected remain very weak. The NMR sensitivity of 23Na is about 9%, while 39K is 0.05% the one of proton (1H). Therefore, radio frequency (RF) coils, which are used to capture these signals, should be optimized for a given anatomical structure in order to improve the SNR. The goal of this work is to develop two separate RF coils which would enable high-resolution in vivo 23Na MRI of the human eye and in vivo 39K MRI of the human heart at 7.0 Tesla. To achieve these goals, the six-channel transmit receive 23Na coil array and a four/two-channel 1H/39K coil array have been designed, built and tested. The performance of the developed RF coils has been evaluated using RF circuit, electromagnetic field (EMF) and specific absorption rate (SAR) simulations. Phantom as well as in vivo experiments involving several healthy volunteers have been conducted. The experiments have revealed that the developed six-channel transmit/receive coil array supports in vivo 23Na MRI of the human eye with nominal spatial resolution of (1.0 x 1.0 x 1.0) mm3 and within scan time of 10 minutes. This work also demonstrates that the proposed four/two-channel 1H/39K coil array enabled obtaining the world’s first in vivo 39K image of the human heart with nominal spatial resolution of (14.5 x 14.5 x 14.5) mm3 and within total scan time of 30 minutes. The results demonstrate that sodium content in the lens is distinguishable from sodium content in the aqueous and vitreous humor. There is strong evidence that sodium concentration in the compartments of the eye should change in diseases like cataract, glaucoma and ocular melanoma. The broad roles of this element in processes related to eye physiology suggest a range of questions for ophthalmological investigations. This work also shows that in vivo potassium MRI of the human heart is feasible. Previous reports, suggesting that potassium concentration is expected to alter in arrhythmia, ischemia or irreversible injury to miocytes, provides encouragement for future in vivo studies involving patients who suffer from various cardiovascular disorders.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2020
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Wenz, Daniel
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 6Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier URI
- https://refubium.fu-berlin.de/handle/fub188/28051