Back to search

Freie Universität Berlin

Influence of Right Ventricular Leads of Cardiac Devices on Tricuspid Valve Function and Occurrence of Tricuspid Regurgitation

Abstract

dc:description.abstract

Introduction: In Germany, many Pacemakers (PM) and cardiac rhythm devices are implanted at specialized clinics each year. However, the impact of right ventricular leads on the tricuspid valve (TV) function as well as possible effects on mortality are largely unexamined. Previous studies show heterogeneous results. This study aims at investigating whether the presence of right ventricular PM leads influences TV function. Methods: The study was conducted retrospectively at the Charité Universitätsmedizin Berlin and included a total of 261 patients, of whom 123 had undergone cardiac device implantation between 2010 and 2016 (PM group), and 138 controls. An initial transthoracic echocardiography (TTE), and up to three follow-up TTEs at one month, 12 months and after a minimum of one year were evaluated for each patient. Primary outcome was the Grade of Tricuspid Regurgitation (TR). Additional secondary parameters were: TR Vmax, tricuspid annular plane systolic excursion (TAPSE), left ventricular ejection fraction (LVEF), systolic pulmonary artery pressure (SPAP), central venous pressure (CVP), vena contracta width, proximal isovelocity surface area (PISA) and right atrium volume (RA Vol). The cumulative survival probability for both groups was analyzed using the Kaplan- Meier Estimate. Results: The pacemaker group’s median TR Grading was significantly greater initially and long- term than that of the control group (p=0.024 and p=<0.001). TR Grading worsened long-term more often in the PM group (N=34, 44%) than in the control group (N=23, 27%). The PM group’s overall left-heart function (LVEF) was significantly lower at all examination periods (p=always <0.005) and the right heart function (TAPSE) was almost always significantly worse (p=<0.05 for initial, mid- and long-term examination). Both parameters remained stable over time. The PM group’s mean RA Vol was significantly greater initially (p=0.018), however no great change was observed by the end of this study. Results pertaining to SPAP, vena contracta and PISA showed no disparities between groups. The PM group had a significantly lower probability of cumulative survival (p=0.016). Conclusion: Patients with a cardiac rhythm device had overall worse parameters pertaining to TV function and right and left heart function. However, most of these parameters did not majorly fluctuate or aggravate over time thus suggesting that the presence of an RV lead does not influence TV function. Additionally, this study implies that patients with a PM have a higher mortality.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Roczek, Emily
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 8

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Roczek, Emily. Influence of Right Ventricular Leads of Cardiac Devices on Tricuspid Valve Function and Occurrence of Tricuspid Regurgitation. 2021. https://doi.org/10.17169/refubium-28872