Freie Universität Berlin
Myocardial strain: On agreement and reproducibility of a new parameter to determine ventricular function
Abstract
dc:description.abstractBackground. Strain is a novel quantitative parameter to determine heart function and heart failure by measuring the shortening of the heart muscle from diastole to systole. Using cardiovascular magnetic resonance imaging (CMR), various techniques are available to quantify strain: tagging (TAG), feature tracking (FT) and strain-encoding (SENC)/ fast strain-encoding (fSENC). In echocardiography, strain can be calculated using speckle-tracking (STE). Whereas the problem of inter-vendor variability of different ultrasound systems is well analyzed for STE, it is unknown if the choice of the magnetic resonance imaging scanner influences CMR-strain measurements. Moreover, important aspects of reproducibility have not been thoroughly explored for many modalities and techniques, such as fSENC, limiting the use of strain measurements in clinical routine. This dissertation focuses on a study published by our working group to address these obstacles regarding the fSENC-technique. Furthermore, it integrates the results into a clinical context and compares the analysis to research on other modalities and techniques. Methods. Fifteen healthy volunteers were scanned at three centers with different 3T magnetic resonance scanners from leading vendors: the German Heart Institute Berlin, the Charité University Medicine Berlin-Campus Buch and the Theresien-Hospital Mannheim. Every volunteer received four fSENC-scans with a uniform imaging protocol, interrupted by a fifteen-minute break between scan number two and three. Left ventricular (LV) global longitudinal strain (GLS) and circumferential strain (GCS) were analyzed (Myostrain 5.0, Myocardial Solutions). Inter-vendor agreement was determined using Bland-Altman analysis. Test-retest reproducibility and inter- and intra-observer reproducibility were calculated using intraclass correlation (ICC) and coefficients of variation (CoV). The results are demonstrated and compared to studies on different modalities and techniques for strain analysis. Results. fSENC showed good to moderate inter-vendor agreement between different sites (bias of 0.01-1.88%) and excellent test-retest reproducibility, regardless of the vendor. Inter- and intra-observer agreement of all global strain analyses were excellent. Conclusion. Our findings show that a bias should be expected when using fSENC in volunteers. Although this bias needs to be validated in a larger cohort and in patients, it should be considered when planning multi-center studies and when comparing fSENC scans that were acquired at different sites. The excellent test-retest reproducibility and intra- and inter-observer reproducibility reflect the reliability of fSENC, which is in accordance with other modalities and techniques to determine strain.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Erley, Jennifer Sigrid Myrtle
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 6Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-29532-9
- Identifier URI
- http://dx.doi.org/10.17169/refubium-29276