Freie Universität Berlin
Cortical somatosensory evoked potential amplitudes and severity of hypoxic-ischemic encephalopathy after cardiac arrest
Abstract
dc:description.abstractIntroduction: Bilaterally absent median nerve cortical somatosensory evoked potentials (SSEPs) are a reliable prognostic parameter to early predict poor outcome in comatose cardiac arrest (CA) patients if sufficient recording criteria are fulfilled. However, the prognostic significance of cortical SSEP amplitudes and tolerable cortical noise level remain uncertain. Methods: We investigated the prognostic value of cortical SSEP amplitudes to predict poor and good outcome after CA. First, we prospectively determined cortical broadband SSEP amplitudes and clinical outcome upon intensive care unit discharge. Clinical outcome was assessed according to cerebral performance category (CPC) scale and dichotomized in good (CPC 1 – 3) and poor outcome (CPC 4 – 5). Second, we retrospectively studied amplitudes of high-frequency (600 Hz) SSEP components. Third, we retrospectively investigated cortical broadband SSEP amplitudes and severity of hypoxic-ischemic encephalopathy (HIE) in CPC 5 patients histopathologically evaluated by postmortem brain autopsies and dichotomized into no/mild and severe HIE. Results: Of 293 CA patients, 0.62 μV was the lowest cortical broadband SSEP amplitude of 156 good outcome patients whereas all 78 patients with lower amplitudes had a poor outcome. Prognostic parameters, case reviews and amplitude distribution of CPC 4 patients strongly indicated absence of severe HIE in patients with cortical broadband SSEP amplitudes above 2.5 μV. We detected early and late high-frequency (600 Hz) SSEP components in 146 and 95 of 302 included patients. High amplitudes of late high-frequency (600 Hz) SSEP components were mainly found in patients with high cortical broadband SSEP amplitudes. We assessed severe HIE unlikely in patients with late high- frequency (600 Hz) SSEP component amplitudes above 70 nV. Of 187 deceased CA patients with brain autopsy, the lowest cortical broadband SSEP amplitude in 24 patients with no/mild histopathological HIE was 0.5 μV. We found severe histopathological HIE in all 26 patients with cortical broadband SSEP amplitudes below 0.5 μV of whom 21 patients had bilaterally absent cortical SSEPs. Conversely, considering confounders the highest cortical broadband SSEP amplitude in patients with severe histopathological HIE was 2.7 μV. Conclusion: Cortical noise levels should not exceed 0.5 μV to avoid falsely classifying cortical SSEPs as bilaterally absent in good outcome patients. Bilaterally absent cortical SSEPs and cortical broadband SSEPs below 0.5 μV are reliable prognostic parameters for severe HIE evaluated by clinical outcome and brain autopsy. Cortical broadband SSEP amplitudes above 2.7 μV and late high- frequency (600 Hz) SSEP component amplitudes above 70 nV suggest absence of severe HIE.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Endisch, Christian
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-30156-1
- Identifier URI
- http://dx.doi.org/10.17169/refubium-29898