Back to search

Freie Universität Berlin

In-vivo-Funktionalität transvenös implantierter, dezellularisierter, tissue engineerter Pulmonalklappen im Großtiermodell über ein Jahr

Abstract

dc:description.abstract

Introduction: Many congenital heart defects and degenerative valve diseases require replacement of heart valves in children and young adults. Transcatheter xenografts degenerate over time. Tissue engineering might overcome this limitation by providing heart valves with the ability for self-repair. In a European consortium, a transcatheter decellularized tissue engineered heart valve (dTEHV) was developed. A first prototype showed progressive regurgitation after 6 months due to a suboptimal design. A new geometry was developed using computational fluid dynamics (CFD) simulations leading to a second generation of dTEHV. Methodology: dTEHV based on vascular derived cells on a polymeric scaffold and a nitinol stent were transvenously implanted in 18 sheep. Valve functionality was assessed via MRI, CT and intracardiac echocardiography for one year. Regurgitation fraction > 30 % in MRI was set to be the premature study endpoint. Histology was performed on the explanted valves to assess cells and tissue composition. Results: After the first implantations, the manufacturing protocol for valve production was adapted leading to a stable design of dTEHV of which ten valves were implanted. nine out of ten animals then reached the set follow-up time of 52 weeks, one animal had to be euthanized after 24 weeks due to regurgitation fraction exceeding 30% via MRI measurements. Pressure measurements showed no elevated pressure differences between right ventricle and pulmonary artery indicating good opening function. No elevated pressure gradients were detected by ICE throughout the complete follow-up. After implantation eight animals showed no and only two animals mild insufficiency in ICE. Valve functionality was generally good during follow-up. Median regurgitation fraction by MRI was 9 % after implantation and 14,2 % after 52 weeks. At explantation, one animal showed no, six mild and only two animals moderate insufficiency in ICE. No severe insufficiencies were detected. Histological analyses showed complete engraftment of the dTEHV, endothelialization of leaflets and graft wall, very few scaffold remnants were visible. Leaflets consisted mainly of collagenous tissue, no elastic fibers were found. Adaptive leaflet remodeling was visible in all animals. No fusion between leaflet and graft wall was found. Conclusion: The improved design geometry developed using CFD-simulations resulted in very good valve functionality of the implanted dTEHV over a period of 52 weeks. Failing mechanisms of the first generation of dTEHV were largely overcome. However, sufficient in-vivo functionality needs to be proven over an even longer period of time.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bruder, Leon
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-30215-5

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Bruder, Leon. In-vivo-Funktionalität transvenös implantierter, dezellularisierter, tissue engineerter Pulmonalklappen im Großtiermodell über ein Jahr. 2021. https://refubium.fu-berlin.de/handle/fub188/30215