Freie Universität Berlin
Vergleich der Filtration der oberen und unteren Extremität erhoben mittels venöser Verschlussplethysmographie bei perioperativen Tumorpatienten
Abstract
dc:description.abstractAbstract Background: Microvascular fluid filtration is the basis for metabolism and fluid exchange in the human body. However, the characterization of filtration in the perioperative context has so far been insufficiently investigated and current studies on this topic are missing. To estimate filtration, venous congestion plethysmography (VCP) has proven to be a fast and noninvasive method. The VCP can be performed at the same time on arm and leg, but in a number of clini-cal situations there is a limitation of the leg measurement by a limited space offer or operating conditions. Most data published so far to validate the method have been collected on the leg. Whether the method for simplified measurement is interchangeable is still unclear. The aim of the presented work was therefore to check whether measurements of the fluid filtration on the arm and leg on non-sedated, postoperative patients with ovarian carcinoma are interchangeable. Methods: The filtration was measured by means of VCP simultaneously on arm and leg at four perioperative time points. A stasis of the venous discharge with a preserved arterial influence was generated under occlusion of the limb. In parallel, the volume change (VC) on arm and leg between the 3rd and 6th minute (VC6-3min) was detected and the filtration was determined. The filtration data of the arm and leg were then compared with one another and the relationship with the occurrence of peripheral edema was considered. Results: Overall, 74 paired measurements from a total of 29 female patients were included in the study. Perioperatively, a significantly higher VC6-3min was seen on the arm than on the leg. (0.6 % (0.4, 0.9) vs. 0.4 % (0.3, 0.6), P = 0.008). A poor trending between the two methods arm and leg could be achieved with the aid of polar and Bland-Altman analysis (bias +0.23 %, lim-its of agreement (LOA) -1.1 to 1.6 %, angular bias –2.5°, radial LOA -82 to +77°). Patients with postoperative edema had higher VC6-3min values on the arm than patients without edema (0.7 % (0.5; 1.0) vs. 0.5 % (0.4; 0.6), P < 0.001). The VC6-3min on the leg was not different for patients with and without edema. Conclusion: Measurements on the arm and the leg using VCP for the determination of the VC6-3min on perioperative awake patients are not interchangeable. The perioperative measurement of fluid filtration by means of VCP should be performed primarily on the arm because of the established relationship of VC6-3min on the arm with the occurrence of postoperative peripheral edema.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Heinig, Sandra
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-30843-0
- Identifier URI
- http://dx.doi.org/10.17169/refubium-30582