Back to search

Freie Universität Berlin

Die pull-back Technik für die 532 slim modiolar Elektrode

Abstract

dc:description.abstract

Introduction: The distance between the modiolus and the electrode array has become the focus of many discussions and studies. Positioning the electrode array closer to the spiral ganglion with the goal of reducing the current spread has been shown to improve hearing outcomes. Perimodiolar electrode arrays can be complemented with an extremely careful surgical maneuver called the pull-back technique. This study is focused on the recently developed 532 slim modiolar electrode. Objective: To investigate intracochlear movements and pull-back technique for the 532 slim modiolar electrode. Study design: Experimental. Setting: Tertiary referral center. Material and Methods: A decapping procedure was performed on five temporal bones. The electrode array was inserted and the intracochlear movements were microscopically examined and digitally captured. Three situations were analyzed: the initial insertion, over-insertion and pull-back position. The position of the three white markers of the electrode array in relation to the round window was evaluated when performing these three actions. Results: The initial insertion achieved an acceptable perimodiolar position of the electrode array, but there was still a gap between the mid-portion of the array and the modiolus (the first white marker was visible in the round window). When we inserted the electrode a little deeper, the mid-portion of the array was pushed away from the modiolus (the second and third white markers were visible in the round window). After applying the pull-back technique, the gap observed during the initial insertion disappeared, resulting in an optimal perimodiolar position (the first white marker was once again visible in the round window). Conclusion: This temporal bone study demonstrated that applying the pull-back technique for the 532 slim modiolar electrode allowed a closer proximity to the modiolus when the first white marker of the electrode array was visible in the round window.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Riemann Torres, Conrad
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-31048-8

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Riemann Torres, Conrad. Die pull-back Technik für die 532 slim modiolar Elektrode. 2021. https://refubium.fu-berlin.de/handle/fub188/31048