Back to search

Freie Universität Berlin

Development and optimization of methods for quantitative Magnetic Resonance Imaging: QSM and DCE-MR

Abstract

dc:description.abstract

Goal: Development and optimization of quantitative Magnetic Resonance Imaging (MRI) methods to provide enhanced image contrasts which can be used as potential biomarkers. Methods: To achieve this goal, two studies were carried out: (i) optimization of Quantitative Susceptibility Mapping (QSM) in the brain. This study, based on 16 healthy volunteers, has consisted in evaluating reproducibility and consistency of QSM reconstructions obtained at 1.5T and 3T and in optimizing a sequence acquisition protocol to increase image contrast-to-noise ratio (CNR) at 1.5T. Four spoiled gradient echo (SPGR) acquisition sequences with different acquisition bandwidths were tested. (ii) implementation of a non-rigid respiratory motion correction (MC) framework for dynamic contrast enhanced MR (DCE-MR) imaging of the liver. DCE-MRI data was acquired at 3T during free breathing for 5 min, using a 3D T1-weighted Golden Angle Radial Phase Encoding (GRPE) sequence. Non-rigid respiratory motion information was extracted from the acquired data and used in a motion corrected image reconstruction to obtain high quality DCE-MRI images with temporal resolution of 6 s and isotropic resolution of 1.5 mm. An extended Tofts’ model was fitted to the dynamic datasets, yielding quantitative parametric maps of endothelial permeability using the hepatic artery as input function. This new technique was evaluated on 11 oncological patients. Results: As for the evaluation of reproducibility and consistency of QSM across field strengths in (i), all four acquisition sequences reported very good correlation (Pearson correlation coefficient R ≥ 0.96, widest limits of agreement I from -18.7 to 25.8 ppb). The CNR evaluation reported a statistically significant increase (p < 0.05) in four out of seven regions of interest (ROIs) for the lowest bandwidth employed with respect to the highest (25% increase in CNR of caudate nucleus). Motion correction in (ii), successfully removed respiratory motion artifacts and ensured accurate alignment between time points in the DCE-MR time-series, improving the average CNR of hepatic lesions in later phases of DCE-MR images by 47% (p < 0.01). CNR of endothelial permeability derived from motion corrected data was improved by 62% (p < 0.01) compared to images without motion correction. Motion correction also led to better identification and differentiation of pathologies such as hemangiomas, cysts and necrotic core tumors. Conclusions: Both the optimized QSM acquisition protocol for 1.5T and the 3D non-rigid respiratory motion correction framework for DCE-MR images presented in this thesis improved the quality of quantitative MR images and led to a signfician increase of CNR over various features of interest.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ippoliti, Matteo
Committee member dc:contributor.committeemember
  • N.N

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-31068-1

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ippoliti, Matteo. Development and optimization of methods for quantitative Magnetic Resonance Imaging: QSM and DCE-MR. 2021. https://refubium.fu-berlin.de/handle/fub188/31068