Back to search

Freie Universität Berlin

The effect of GPi-DBS on automatic and controlled movement in dystonia

Abstract

dc:description.abstract

Dystonia is a disabling movement disorder characterized by involuntary sustained or intermittent muscle contractions and abnormal posture. The classification system for dystonia is based on clinical characteristics (axis I) including the anatomical distribution of the affected body part, the etiology, and the age of onset (axis II). The pathophysiology of dystonia is not fully understood yet. However, a growing body of empirical evidence suggests that it is not attributed to one brain region, but rather that it could arise from abnormal sensorimotor network activity. Although its mechanism of action is not fully understood, deep brain stimulation (DBS) of the Globus pallidus interna (GPi) is a successful treatment for dystonia. The aim of our behavioral study is to explore the effect of GPi-DBS on the cognitive and kinematic aspects of automatic and controlled movements in dystonia. Furthermore, we intended to explore the role of the GPi as the main output of the basal ganglia (BG) in the different movement phases (initiation and execution) and to gain more insight on the pathophysiology of dystonia. Sixteen patients with dystonia undergoing pallidal deep brain stimulation and 16 age-matched healthy controls participated in a visuomotor tracking task requiring normal (automatic) and inverted (controlled) reaching movements. We found that GPi-DBS does not affect proactive inhibition and does not exert an instantaneous effect on the reaction time in the automatic and controlled conditions. GPi-DBS may decrease the average error and improve the movement efficiency in the controlled condition. However, it negatively influences the efficiency of automatic movement performance. Our results suggest that GPi-DBS may exert its effect by interfering with the output signal of the GPi. Furthermore, this study showed that GPi-DBS induces bradykinesia in the automatic condition, quantified by decreasing the peak velocity, which is a common clinical side-effect of GPi-DBS in dystonia.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Al Ajia, Moaz
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-31355-4

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Al Ajia, Moaz. The effect of GPi-DBS on automatic and controlled movement in dystonia. 2021. https://refubium.fu-berlin.de/handle/fub188/31355