Back to search

Freie Universität Berlin

A 3D Multi-channel convolutional neural network for classification of prostate cancer using multiparametric MR imaging

Abstract

dc:description.abstract

Objectives: To compare the diagnostic performance of the newly developed convolutional neural network (CNN) in classification of the significance of prostate cancer using multiparametric magnetic resonance imaging (mp-MRI) against other similar approaches and the standard clinical assessment reported in the literature. Methods: This is a retrospective study with a total of 200 patients (318 suspicious lesions) who received an MRI scan with three different pulse sequences (anatomic T2 weighted (T2w), diffusion-weighted imaging (DWI) with derivation of apparent diffusion coefficients (ADCs), and K-trans from dynamic contrast-enhanced MRI (DCE-MRI)), which served as an input for the CNN that is presented in this study. On the other hand, each patient in the dataset has one or more prostate lesions with their corresponding biopsy results which were used as the training and test labels. This study presents a novel neural network architecture that processes 3D images directly with the least manual interaction possible. This network was trained and evaluated on different individual and combinations of mp-MRI sequences which, in turn, outlines the diagnostic role, the benefits and the effects of each individual MRI sequence on the overall performance of the network. The obtained results were evaluated using widely used statistical values such as accuracy, area under the curve (AUC) sensitivity and specificity. Results: When using the receiver operating characteristic (ROC) curve analysis, our 3D developed network had the highest average AUC value of 89.7% for input combination of ADC, DWI and K-trans while the rest of the mp-MRI combinations resulted in a significantly inferior performance in terms of AUC, sensitivity and specificity where p-value of 0.00025 was obtained when using T2w, ADC, and DWI; and 0.02 when using T2w and K-trans. Individual mp-MRI sequences had an AUC between 89.0% (88.6% sensitivity and 90.0% specificity) to 91.0% (81.2% sensitivity and 90.5% specificity). The effect of lesion size and volume was tested and showed no significant effect on the network’s performance. Conclusion: Our presented study shows that the 3D developed network which, requires minimal manual interactions, can process an input of mp-MRI and achieves very comparable results to the performance values of the reported experienced radiologist. Furthermore, this study shows that the size and the volume of the suspicious lesion have no significant effect on the performance of the network.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Aldoj, Nader
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-31907-3

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Aldoj, Nader. A 3D Multi-channel convolutional neural network for classification of prostate cancer using multiparametric MR imaging. 2021. https://refubium.fu-berlin.de/handle/fub188/31907