Back to search

Freie Universität Berlin

Characterization of the emissions of volatile organic compounds from polymer-based consumer products: towards a realistic exposure assessment

Abstract

dc:description.abstract

While technological improvements enable the production of a myriad of new products, assuring consumer safety has become an essential preoccupation for authorities. Indeed, consumers are potentially exposed to chemical risks with health consequences upon product usage. Polymer-based products have proliferated around the globe in the last decades and are appreciated for their cheap and flexible usage. However, they also often release hazardous substances that may be ingested, dermally absorbed or inhaled. This thesis focuses on the emissions of volatile organic compounds (VOCs) from plastic-based and wooden consumer products such as toys. Exposure data to apprehend the risks arising from such articles are scarce although the affected consumer group of children represent a vulnerable population. This data gap on exposure assessment is largely due to a lack of adequate analytical methods. Strategies existing for emission measurements from construction products are unsuitable for consumer products: Large emission test chambers (50 L to 20 m3) are not adapted to consumer product size. Alternative and more economical methods such as dynamic headspace (DHS, 20 mL or 1 L), microchambers (44 or 114 mL), glass chambers (24 L) and the flask method were investigated in this thesis. DHS sampling allowed semi-quantitative emission results and was further used for sample pre-selection. Both microchambers and 24 L glass chambers provided results that correlate with bigger emission test chambers: These devices would be suitable for market surveillance. The standardized flask method for formaldehyde emissions from wooden toys was not appropriate for exposure assessment. Furthermore, an assessment of the potential exposures from polymer-based consumer products was carried out. First, the samples were selected via DHS sampling and the constituting polymers were characterized. Then, the high-emitting samples were studied in conventional emission test chambers, 24 L glass chambers or microchambers. An exposure assessment was performed considering indoor air scenarios for short-term (a few hours) to long-term (28 days) exposure. Results were compared to existing toxicologically based guideline values. Emitted concentrations from single products do not typically exceed thresholds. However, scenarios with numerous products or smaller breathing zones are more concerning. Indeed, the cyclohexanone guideline value was exceeded during the study of the exposure from costume masks investigated with a doll’s head setup. This work is the first to systematically examine strategies for inhalation exposure assessment in official control laboratories. The exposure assessment data generated in the frame of this thesis give insights in the possible health risks associated with the use of polymer-based consumer products.

Degree

thesis:*
Department dc:contributor.department
Biologie, Chemie, Pharmazie
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Even, Morgane
Committee members dc:contributor.committeemember
  • Luch, Andreas
  • Klinger, Daniel

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-32179-5

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Even, Morgane. Characterization of the emissions of volatile organic compounds from polymer-based consumer products: towards a realistic exposure assessment. 2021. https://refubium.fu-berlin.de/handle/fub188/32179