Freie Universität Berlin
Binokulare Trifokalität - Vergleich klinischer Ergebnisse bifokaler Multifokallinsen unterschiedlicher optischer Systeme
Abstract
dc:description.abstractBackground and Aims: The binocular trifocality represents a form of monovision which uses the implanation of bifocal intraocular lenses with different near addition to achieve good uncorrected binocular vision in the near, intermediate and far distance and spectacle independence. Furthermore this study compares 3 optical designs for multifocal lenses (refractive, diffractive, refractive-diffractive hybrid) particularly in regards to contrast vision, contrast sensitivity, optical phemona, and patient satisfaciton. Methods: This prospective study was conducted at Charité Universitätsmedizin Berlin from 2013 to 2015 and 45 patients (90 eyes) underwent surgery with the implantation of a bifocal lens with lower-addition in the distance-dominant eye and a higher-addition bifocal lens of the same optical system in the fellow-eye. 3 groups of 15 patients each received either the refractive LS-MF20 and LS-MF30 (Oculentis GmbH), the diffractive Tecnis ZKB00 and ZLB00 (Abbott Medical Optics) or the refractive-diffractive hybrid ReSTOR SV-25 and SN6A multifocal lenses. Lens perfomances were evaluated with assessment of visual acuity in the near, intermediate, distance and defocus curves. Furthermore the contrast sensitivity and vision was analyzed with and without glare. Patient satisfaction was explored with the „National-Eye-Institut Refractive Error Quality of Life Instrument“. Results: All 3 groups achieved a spherical equivalent of -0.33 to -0,07 diopter. There was no significant differences in the visual acuities in the near (0,07 logMAR), intermediate (-0,02 logMAR) or distance (0,0 logMAR). The defocus curves of all groups showed a binocular enhanced near-range. The refractive group achieved this between -1.00 to -2.50 diopter, the diffractive group from -1.00 to -3,00 diopter and the hybrid group from -2.00 to -3.00 diopter. The uncorrected low-contrast vision showed no significant group differences. The refractive group had significant disadvantage in low-contrast vision with glare. Mesopic contrast sensitivity of the hybrid group was significantly better in comparison to the refractive and diffractive groups with ambient light level of 0.032 cd/m2 und 0.1 cd/m2. The hybrid lenses were furthermore significantly superior in mesopic contrast sensitivity in 0.1 cd/m2 with glare to the refractive lenses. Patient satisfaction with the refractive correction achieved high levels of 90% in all 3 groups without significant differences in any categories. Conclusion: The binocular trifocality achieved good uncorrected visual acuities and therefore high spectacle independence. Patient satisfaction was high. Regarding contrast sensitivity and low-contrast vision the refractive-diffractive optical system proved superiority.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2021
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Pham, Annabell Thi Nhu-Hoa Delphine Margarita
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 3Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-32290-6
- Identifier URI
- http://dx.doi.org/10.17169/refubium-32017