Back to search

Freie Universität Berlin

Vergleich der Auswirkung zweier Bettsysteme mit hoher bzw. niedriger Wärmekapazität auf die Schlafqualität

Abstract

dc:description.abstract

Objective: About 20 % of the German population suffers from sleep disorder, which can lead to serious health consequences. In the context of sleep hygiene consultation an optimal sleep area is frequently suggested. This also includes the constitution of the mattress. This research draws a comparison between a conventional bed system with low heat capacity (MN) and a gel coated bed system with a higher heat capacity (MH). On the basis of these, the study examines to what extent the quality of the bed systems effects sleep quality. Methods: By applying a double blind and randomized cross-over study design, 36 healthy subjects are investigated on two nights in a sleep lab. The subjects slept one night on each of the two mattresses (MH and MN) at the interval of one week. The data on the subjective sleep quality was gathered by the Karolinska Sleepiness Scale (KSS), the Sleep Questionnaire-A (SF-A), as well as a Charité Questionnaire on sleep comfort. Data on the objective sleep quality was gathered by polysomnographic analysis. Additionally, body core temperature (CBT, VitalSense® Core Temperature Capsule, Equivital EQ02 LifeMonitor), mattress’ temperature and skin temperature (DS 1922L, iButtons®; Maxim) were continuously measured during the night. This study focused on the N3 sleep latency, total sleep time, sleep efficiency, as well as the distribution of sleep stages. Results: Sleep on MH exhibited a selective increase in SWS (in minutes) in comparison to MN (11,4%, p =0,01). In addition, MH induced a greater reduction in SWSL (43,1 ± 30,8 vs. 51,8 ± 42 in minutes) and caused an increase of TST (396,6 ± 43,46 vs. 388,4 ± 43,37 in minutes) and sleep efficiency (83 ± 9 vs. 81 ± 9 in %). The subjective data showed almost no differences in sleep quality, exemplarily shown by the SF-A (2,8 ±0,7 vs. 2,7 ± 0,6). Conclusion: This study shows that the MH induced reduction of core body temperature is associated to an increase in SWS. In addition, the greater reduction of CBT seems to be linked to a decrease of SWSL and improvement of sleep efficiency. However regarding subjective parameters, there is almost no change in sleep quality. Still the objective results indicate that a mild thermal intervention through the sleep area might influence sleep positively. This could be of particular interest in the field of preventive medicine. Sleep disorders are widespread and the demand for affordable interventions without side-effects is increasing.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Aßmus, Lisa
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Aßmus, Lisa. Vergleich der Auswirkung zweier Bettsysteme mit hoher bzw. niedriger Wärmekapazität auf die Schlafqualität. 2022. https://doi.org/10.17169/refubium-32763