Freie Universität Berlin
Vergleich der Auswirkung zweier Bettsysteme mit hoher bzw. niedriger Wärmekapazität auf die Schlafqualität
Abstract
dc:description.abstractObjective: About 20 % of the German population suffers from sleep disorder, which can lead to serious health consequences. In the context of sleep hygiene consultation an optimal sleep area is frequently suggested. This also includes the constitution of the mattress. This research draws a comparison between a conventional bed system with low heat capacity (MN) and a gel coated bed system with a higher heat capacity (MH). On the basis of these, the study examines to what extent the quality of the bed systems effects sleep quality. Methods: By applying a double blind and randomized cross-over study design, 36 healthy subjects are investigated on two nights in a sleep lab. The subjects slept one night on each of the two mattresses (MH and MN) at the interval of one week. The data on the subjective sleep quality was gathered by the Karolinska Sleepiness Scale (KSS), the Sleep Questionnaire-A (SF-A), as well as a Charité Questionnaire on sleep comfort. Data on the objective sleep quality was gathered by polysomnographic analysis. Additionally, body core temperature (CBT, VitalSense® Core Temperature Capsule, Equivital EQ02 LifeMonitor), mattress’ temperature and skin temperature (DS 1922L, iButtons®; Maxim) were continuously measured during the night. This study focused on the N3 sleep latency, total sleep time, sleep efficiency, as well as the distribution of sleep stages. Results: Sleep on MH exhibited a selective increase in SWS (in minutes) in comparison to MN (11,4%, p =0,01). In addition, MH induced a greater reduction in SWSL (43,1 ± 30,8 vs. 51,8 ± 42 in minutes) and caused an increase of TST (396,6 ± 43,46 vs. 388,4 ± 43,37 in minutes) and sleep efficiency (83 ± 9 vs. 81 ± 9 in %). The subjective data showed almost no differences in sleep quality, exemplarily shown by the SF-A (2,8 ±0,7 vs. 2,7 ± 0,6). Conclusion: This study shows that the MH induced reduction of core body temperature is associated to an increase in SWS. In addition, the greater reduction of CBT seems to be linked to a decrease of SWSL and improvement of sleep efficiency. However regarding subjective parameters, there is almost no change in sleep quality. Still the objective results indicate that a mild thermal intervention through the sleep area might influence sleep positively. This could be of particular interest in the field of preventive medicine. Sleep disorders are widespread and the demand for affordable interventions without side-effects is increasing.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Aßmus, Lisa
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 3Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- Identifier URI
- https://refubium.fu-berlin.de/handle/fub188/33039