Back to search

Freie Universität Berlin

Herzfrequenzvariabilität zur Detektion von Abfällen des Schlagvolumens bei experimenteller Blutungssimulation

Abstract

dc:description.abstract

Introduction: Hemorrhagic shock is a potentially life-threatening condition. Therefore, early detection and appropriate intervention of occult bleeding is desirable. However, detection of occult hemorrhage can be difficult, as traditional vital signs like heart rate and blood pressure are not sensitive enough to blood loss. Due to physiological compensatory mechanisms, they may even be sustained stable just before cardiovascular decompensation. These compensatory mechanisms are primarily driven by the autonomic nervous system (ANS). Heart rate variability (HRV) has been used to assess ANS function and thus might be useful in detecting otherwise occult bleeding. Methods: This prospective pilot study investigates the diagnostic value of HRV for the noninvasive detection of progressive central hypovolemia. Central hypovolemia was experimentally simulated using a lower body negative pressure model (LBNP). Over several progressively increased levels of negative pressure (0 mmHg, -15 mmHg, -30 mmHg, -45 mmHg, 0 mmHg) heart rate, blood pressure, stroke volume (SVTTE) as well as HRV in its different domains (time-domain: SDNN, RMSSD, rSDRM, pNN50, NN50; frequency-domain: VLF, rVLF, LF, rLF, HF, rHF, LF/HF, TP; non-linear: SD1, SD2, SD1/SD2, SampEn, AppEn) were measured. Parameter changes as a consequence of reduced central volume were evaluated statistically and a correlation analysis (SVTTE vs. HRV parameters) was conducted. Furthermore, a Gray Zone Approach (GZA) with receiver operating characteristic curves regarding a decline in SVTTE of > 20 % was conducted. Results: A total of 30 male, healthy volunteers were analyzed. Application of LBNP caused progressive reductions of SVTTE successfully. Nonparametric analysis of longitudinal data showed significant p-values (p<0.05) for all HRV parameters. Furthermore, post-hoc analysis showed a significant deviation (p<0.05) from baseline values for some HRV parameters at a chamber pressure of -15 mmHg (SDNN, RMSSD, NN50, VLF, rLF, HF, TP and SD1). Intraindividual correlation analysis showed strong correlations (|ρ| > 0.5) for NN50, pNN50, RMSSD, SD1 and HF. Repeated Measures Correlation analysis showed strong correlations (|ρ| > 0.5) for SD1, RMSSD, SD1/SD2, pNN50, and rSDRM. The GZA showed significant differences between groups for NN50, rVLF, LF, and rHF. Areas under the curves were <0.7. Conclusion: Progressive central hypovolemia is well reflected by HRV. Several parameters also showed a significant reaction in mild central hypovolemia already. HRV analysis could thus be helpful in the detection of otherwise occult hemorrhage. However, its diagnostic value based on the GZA is limited because of explicit interindividual variability.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wiegank, Ludwig
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Wiegank, Ludwig. Herzfrequenzvariabilität zur Detektion von Abfällen des Schlagvolumens bei experimenteller Blutungssimulation. 2022. https://doi.org/10.17169/refubium-32917