Back to search

Freie Universität Berlin

Improvement of the diagnosis of implant-associated infection

Abstract

dc:description.abstract

Treatment of implant-associated infections essentially differs from the one of aseptic implant failure. Therefore, an accurate diagnosis of the underlying cause of implant failure is crucial. Conventional diagnostic methods such as culture or leukocyte count of synovial fluid have limited sensitivity and specificity. Therefore, novel, innovative strategies for improved (more accurate and faster) diagnosis of implant-associated infections are needed. The aim of this work was to improve the diagnosis of implant-associated infections: (1) to evaluate the performance of D-lactate (bacterial metabolite) in synovial fluid as independent diagnostic marker; (2) to investigate the activity of chemical methods (i.e. ethylenediaminetetraacetic acid and dithiothreitol) and mechanical methods (i.e. sonication) for biofilm dislodgement and evaluate their potential role in the routine microbiological diagnosis; (3) to investigate the influence of the implants material type, such as polyethylene, titanium and cobalt-chromium alloy, on the biofilm formation. Results showed that the optimal cut-off of synovial fluid D-lactate to differentiate periprosthetic joint infections (PJI) from aseptic failure (AF) was 1.3 mmol/L with sensitivity and specificity more than 94% and 88%, respectively, and was comparable to synovial fluid leukocyte count. The comparison of the ability of chemical and physical methods to dislodge bacterial biofilm in an established in vitro model of artificial biofilm showed that sonication dislodges significantly more bacteria compared to chemical method. The results were derived applying three independent methods: colony counts, isothermal microcalorimetry and scanning electron microscopy. Investigating the influence of implants’ biomaterial on microbial adhesion, the results reviled that polyethylene showed larger biofilm burden compared to metal alloys (titanium and cobalt-chromium alloy ), suggesting intrinsic differences in the ability of microorganisms to form biofilms on various biomaterials. This work demonstrated that D-lactate had good performance for the diagnosis of PJI and might be used as a highly sensitive and specific bacterial specific biomarker. In the intraoperative stage, sonication is the most sufficient method for bacterial biofilm dislodgement and bacterial detection. Using sonication, polyethylene showed higher bacterial load compared to metal alloys, indicating that microorganisms have different adhesion affinity on different biomaterials in vivo. Sonication of polyethylene liners may be sufficient to diagnose implant-associated infections rather than using the whole prosthesis.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Karbysheva, Svetlana
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-33322-7

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Karbysheva, Svetlana. Improvement of the diagnosis of implant-associated infection. 2022. https://refubium.fu-berlin.de/handle/fub188/33322