Freie Universität Berlin
Vergleich von Compressed Sensing-basierter und konventioneller MRT-Perfusionssequenzen hinsichtlich der Beurteilbarkeit myokardialer Ischämien in der kardialen Magnetresonanztomographie
Abstract
dc:description.abstractBackground: First pass perfusion imaging is a reliable tool in non-invasive detection of coronary artery disease (CAD) and widely used in clinical routine. We investigated a prototype sequence based on compressed sensing and compared it with a conventional echo perfusion sequence regarding image quality and diagnostic performance. Methods: We recruited patients with an indication for invasive coronary angiography (ICA) due to pathologic first pass perfusion MRI. All patients were examined twice with adenosine stress MRI using the conventional TurboFLASH and the prototype SPARSE sequence. Afterwards they underwent ICA with quantitative fractional flow reserve (FFR) measurements. The angiography was considered as the reference standard for the identification of CAD. Visual stenosis >90% or FFR<0.75 were defining myocardial ischemia. Diagnostic performance of perfusion MRI was estimated by a visual perfusion assessment and the quantification of myocardial perfusion reserves (MPR). We used the signal upslope method and the Fermi function deconvolution model to calculate the MPR. Results: In this study 23 patients were enrolled with the mean age of 69.6±8.9 years, 46% of them were female. Regarding image quality there was no significant difference between the TurboFLASH sequence and the SPARSE sequence (2.9±0.5 vs 3.1±0.7, p=0,06). The SPARSE sequence revealed a higher signal-to-noise ratio (15.6±6.2 vs 13.2±4.2, p<0.01) and contrast-to-noise ratio (52.1±27.4 vs 40.5±17.6, p<0.01) than the TurboFLASH sequence. Visual perfusion analysis using the SPARSE sequence yielded less false-positive perfusion defects than TurboFLASH sequence. Concerning quantitative perfusion assessment both sequences showed similar performances in detecting ischemic areas 9 on a segmental basis with upslope MPR evaluation (TurboFLASH 0.88 ± 0.18 vs. SPARSE 0.77±0.26; p=0.06) and Fermi function deconvolution (TurboFLASH 0.85 ± 0.24 vs. SPARSE 0.76 ± 0.30; p=0.13). Conclusions: Using a compressed sensing-based MRI sequence in perfusion imaging leads to a stable detection of myocardial ischemia in the visual assessment. The prototype sequence SPARSE was non-inferior to the conventional sequence TurboFLASH regarding image quality, signal-to-noise-ratio, contrast-to-noise-ratio and quantitative perfusion assessment.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Stötzner, Arthur
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-33386-3
- Identifier URI
- http://dx.doi.org/10.17169/refubium-33107