Abstract
dc:description.abstractIntroduction: The incidence of periprosthetic hip fractures is increasing due to the high number of hip replacements. Therapy of those fractures remains a challenge to the surgeon regarding complexity and the mostly comorbid patient population. Especially in Vancouver type B1 fracture locking plate systems provide a soft tissue preserving and safe technique. Therefore it is necessary to advance and test new implants. Aim: This study compares the hinge system of the distal lateral femur plate (LOQTEQ®) with locking attachment plates of a standard implant (L.I.S.S. LCP®) regarding their biomechanical properties and the handling in fixation of periprosthetic femur fractures after hip arthroplasty. We hypothesized that the new LOQTEQ system has superior stability and durability in comparison. Methods: A total of eighteen artificial left femora were randomized in two groups (Group A: LOQTEQ®; Group B: L.I.S.S. LCP®) and prepared by the same surgeon. According to established test protocols, the samples were tested regarding their biomechanical properties (axial stiffness, loads of failure, cycles of failure, mode of failure: deformation of 10° and complete fail). Results: Eighteen artificial left femurs were randomized in two groups (Group A: LOQTEQ®; Group B: L.I.S.S. LCP®) and tested until failure. Failure was defined as 10° varus deformity and catastrophic implant failure (loosening, breakage, progressive bending). Axial stiffness, loads of failure, cycles of failure, modes of failure were recorded. The axial stiffness in Group A with 73.4 N/mm (SD +/− 3.0) was significantly higher (p = 0.001) than in Group B (40.7 N/mm (SD+/− 2.8)). Group A resists more cycles than Group B until 10° varus deformity. Catastrophic failure mode was plate breakage in Group A and bending in Group B. Conclusion: The modular hinge plates (LOQTEQ®) and the locking attachment plates (LCP®) provide a safe placement of bicortical locking screws around the implant bed. However, LOQTEQ® showed advanced handling due to the extensible angle fixation of the modular hinge system. The distal lateral femur plate (LOQTEQ®) also provides higher primary stability.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Rau, Daniel
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 3Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-33950-2
- Identifier URI
- http://dx.doi.org/10.17169/refubium-33669