Back to search

Freie Universität Berlin

Genauigkeit der Rekonstruktion des approximalen Kontaktpunktes bei konventionellen Set-up-Modellen

Abstract

dc:description.abstract

Set-up models are an important tool for diagnostics and therapy planning in today's dentistry and especially in orthodontics. Set-up models can be manufactured using a classical plaster model or digitally using a computer. Since the set-ups are used for model measurements, they should accurately reflect the morphological characteristics of the dental arch. Both types of models can be used to model the set-up either by means of an impression or a scan. This results in inaccuracies in the approximal area since neither a scanner nor an impression can capture this area. The aim of this study was to determine the accuracy of the contact point reconstruction in conventional set-up models. Materials and methods For this purpose, 7 upper and 7 lower jaw models composed from extracted teeth were produced, molded, separated and processed. The plaster teeth were subsequently digitized using the OraScanner® (OraMetrix®, Richardson, TX, USA) and compared to the approximal surface of the 3-D-models of the reference teeth with the GeoAnalyzer® (OraMetrix®, Richardson, TX, USA) software. Results For the total of 364 remodeled contact points, the evaluations showed a deviation of the clinically relevant mesiodistal position of 0.08 mm (median, X-value). The orovestibular deviation was 0.19 mm (Y-value) and the incisoapical direction 0.34 mm (Z-value). The maximum deviations of the original contact points were 1.6 mm (X-value), 2.67 mm (Y-value) and 5.55 mm (Z-value). A preceeding study by BREUSTEDT was used to draw up data on the remodeling of the contact point in digital set-up models. The comparison of the results did not show any significant differences in the clinically most relevant mesiodistal deviation, but the conventional set-up model turned out to be more accurate in the orovestibular and incisoapical direction. Conclusion The reconstruction inaccuracy of the approximal contact is relatively high. If suppliers of orthodontic appliances based on conventional set-ups provide the orthodontist with specifications for interproximal enamel reduction (IPR) with an accuracy of 0,1mm, these should be checked critically, since the inaccuracy in the manufacturing method, by adding the average error of 0.08 mm, already results in an error of 0.16 mm in the approximal space. Due to the high outliers of up to 5.5 mm, the contact point determination in the set-up should be checked for plausibility by the orthodontist. Whether the differences in the reconstruction of the contact point between the investigated digital and the conventional set-up are of clinical relevance is questionable.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Butzeck, Christian
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 8

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-34247-3

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Butzeck, Christian. Genauigkeit der Rekonstruktion des approximalen Kontaktpunktes bei konventionellen Set-up-Modellen. 2022. https://refubium.fu-berlin.de/handle/fub188/34247