Freie Universität Berlin
Genauigkeit der Rekonstruktion des approximalen Kontaktpunktes bei konventionellen Set-up-Modellen
Abstract
dc:description.abstractSet-up models are an important tool for diagnostics and therapy planning in today's dentistry and especially in orthodontics. Set-up models can be manufactured using a classical plaster model or digitally using a computer. Since the set-ups are used for model measurements, they should accurately reflect the morphological characteristics of the dental arch. Both types of models can be used to model the set-up either by means of an impression or a scan. This results in inaccuracies in the approximal area since neither a scanner nor an impression can capture this area. The aim of this study was to determine the accuracy of the contact point reconstruction in conventional set-up models. Materials and methods For this purpose, 7 upper and 7 lower jaw models composed from extracted teeth were produced, molded, separated and processed. The plaster teeth were subsequently digitized using the OraScanner® (OraMetrix®, Richardson, TX, USA) and compared to the approximal surface of the 3-D-models of the reference teeth with the GeoAnalyzer® (OraMetrix®, Richardson, TX, USA) software. Results For the total of 364 remodeled contact points, the evaluations showed a deviation of the clinically relevant mesiodistal position of 0.08 mm (median, X-value). The orovestibular deviation was 0.19 mm (Y-value) and the incisoapical direction 0.34 mm (Z-value). The maximum deviations of the original contact points were 1.6 mm (X-value), 2.67 mm (Y-value) and 5.55 mm (Z-value). A preceeding study by BREUSTEDT was used to draw up data on the remodeling of the contact point in digital set-up models. The comparison of the results did not show any significant differences in the clinically most relevant mesiodistal deviation, but the conventional set-up model turned out to be more accurate in the orovestibular and incisoapical direction. Conclusion The reconstruction inaccuracy of the approximal contact is relatively high. If suppliers of orthodontic appliances based on conventional set-ups provide the orthodontist with specifications for interproximal enamel reduction (IPR) with an accuracy of 0,1mm, these should be checked critically, since the inaccuracy in the manufacturing method, by adding the average error of 0.08 mm, already results in an error of 0.16 mm in the approximal space. Due to the high outliers of up to 5.5 mm, the contact point determination in the set-up should be checked for plausibility by the orthodontist. Whether the differences in the reconstruction of the contact point between the investigated digital and the conventional set-up are of clinical relevance is questionable.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Butzeck, Christian
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 8Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-34247-3
- Identifier URI
- http://dx.doi.org/10.17169/refubium-33965