Dopplerbasierte kardiale Hämodynamik und elektrokardiographische atrioventrikuläre Erregungssequenz bei Patienten mit atrioventrikulärer Leitungsstörung und Kontrollpatienten mit normaler Leitung
Abstract
dc:description.abstractPQ interval reflects atrial and atrioventricular activation. Prolonged PQ (AVBI) relates to heart failure, atrial fibrillation, and mortality. PQ as a combined parameter may not optimally reflect mechanistic implications of atrioventricular conduction delay. Alternative measures, taking into account atrial and ventricular activation, may better predict unfavourable haemodynamic consequences of delayed atrioventricular conduction. The objective of the study is to compare electrical conduction and Doppler-derived haemodynamics in patients with versus without AVBI and to evaluate the predictive value of alternative measures of AV conduction with regard to unfavourable haemodynamics. Fifty-two patients with AVBI and 52 matched controls without AVBI were enrolled. All patients were hospitalized. Digitalized 12-lead electrocardiograms and echocardiographic examinations were analysed with respect to multiple parameters. ECG and echocardiographic variables were compared between the matched study cohorts. In the combined study group the relationship between time measures (PQ and 6 additional novel measures of AV conduction) and echocardiographic parameters were evaluated (bivariate correlations, logistic regression analysis). The predictive accuracy of time measures with respect to Doppler-derived cardiac performance was compared by ROC- AUC analysis. PQ differed between groups with versus without AVBI [227,5 (212,0;251)ms vs. 182,0 (164,0;190,0)ms;p<0,001)]. Similarly, P wave duration was longer in AVBI compared to controls [127,0 (114,0;136,0)ms vs. 113,0 (102,5;126,8)ms;p<0,001], which was due to longer left atrial [78 (64;101,5)ms vs. 68,5 (58,0;74,0)ms p=0,012] and right atrial [56,0 (44,0; 63,0)ms vs. 47,0 (36,0; 53,5); p=0,023] activation times. QRS duration was longer in AVBI patients [98,5 (90,0;129,5)ms vs. 87,0 (80,0;96,0)ms;p<0,001]. Compared to conventional PQ, PePV6 (end of P wave in V1 to peak QRS in V6) was superior to predict impairment of Doppler-derived LV haemodynamics (LV filling fraction: PQ Δ0,045, PePV6 Δ0,050, AUC 0,681 vs. 0,719, total LV isovolumic time: PQ Δ18ms, PePV6 Δ23ms, AUC 0,619 vs. 0,698, Tei Index LV: PQ Δ0,010, PePV6 Δ0,060, AUC 0,566 vs. 0,626). Similarly, PePV6 was superior versus PQ to predict right ventricular haemodynamics. Dichotomisation at the median of PePV6 re-categorized 20% of all patients, compared to the conventional AVBI definition, as having long vs short AV conduction properties. Beyond the third quartile of PePV6 (148ms) haemodynamic impairment was particularly pronounced, pointing out a possible threshold effect. In this study, 30% of PQ prolongation resulted from delayed atrial activation. A novel parameter of AV conduction (PePV6) outperformed conventional PQ to predict haemodynamic compromise following delayed atrioventricular conduction. Further mechanistic and clinical evaluation of PePV6 should be undertaken.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Auge, Richard Erich
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 8Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- Identifier URI
- https://refubium.fu-berlin.de/handle/fub188/34447