Freie Universität Berlin
The structural integrity of post-and-core (root canal) restorations: a 3D high-resolution in vitro study
Abstract
dc:description.abstractIntroduction: After a root-canal treatment many teeth need to be restored employing post-and-core restorations. The final restoration presents an assortment of biomaterials that must function as a unity to withstand chewing loading in a wet environment. Post-and-core restorations occasionally fail, and their structure usually exhibits voids, air bubbles, or delamination. However, the evaluation of the structural integrity and the attachment between components of post-and-core restorations is a challenge. Objective: To develop and apply a non-destructive methodology to evaluate the presence of defects in post-and-core restorations using x-ray synchrotron imaging techniques. It was hypothesized that the selected techniques would be able to non-destructively detect flaws in the structure of post-and-core restorations. Materials and methods: Human root canal treated upper incisors (n=14) were restored with post-and-core build-ups using prefabricated fiberglass (Dentin Post, Komet) or titanium posts (Kopfstift Titanium Post, Komet), cemented with a self-adhesive resin cement (RelyX Unicem 2, 3M ESPE Dental Products), sustaining cores made with a flowable resin composite (Rebilda DC Quickmix, Voco) that were adhered to the tooth substrate and posts by a universal adhesive system (Futurabond U, Voco). Synchrotron x-ray sources were used for dental sample imaging with phase contrast-enhanced micro-CT (PCE-CT), while single fiberglass posts were imaged with PCE-CT and synchrotron x-ray refraction radiography (SXRR). The reconstructed volumes were segmented, and the data were analysed manually (by a single operator) and digitally in 2D and 3D. The generated data were tabulated and used for statistical analysis. Results: The resulting images from PCE-CT of post-and-core restored teeth revealed the presence of gaps between tooth and cement in ~45% of the interface in the cervical area of the restoration. Endodontic epoxy-based sealer was found in ~10% of the interface. No gaps between post and cement were observed, as well as no statistical difference between fiberglass and titanium post groups for all measured parameters. PCE-CT was suitable to reveal gaps between the adhesive system from the core and the tooth substrate. The segmented gaps were non-uniformly distributed and occupied on average ~34% of the interface and were between 2 and 16 µm thick. PCE-CT and SXRR revealed the impact of bur trimming of fiberglass posts for canal fitting. The regions affected by trimming showed a strong accumulation of defects like splinters, cracks, and fragments of glass fibres extending from the bur-touched surface to 50 µm deep in the post structure. Conclusion: The cutting-edge non-destructive imaging technology used in the present work is invaluable for revealing the defects in post-and-core restorations. The identified defects are possible causes of treatment failure. Further work is needed to show the progressive effect of defects under load over time.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Prates Soares, Ana
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-34904-2
- Identifier URI
- http://dx.doi.org/10.17169/refubium-34622