Der Hitzeflusssensor als vielversprechende Alternative zur Messung der Körperkerntemperatur während des zielgerichteten Temperaturmanagements

Abstract

dc:description.abstract

Background: The use of targeted temperature management (TTM) after return of spontaneous circulation (ROSC) has improved the neurological outcome for patients with survived cardiac arrest. During this therapy precise measuring of the core body temperature (CBT) is integral as deviations from the recommended temperature might result in side effects such as arrhythmias, electrolyte imbalances, or infections. However, current measuring techniques are either invasive, imprecise, or difficult to use. A disposable, non-invasive temperature sensor using the heat flux approach (Double Sensor) has already been tested in different preclinical and intraoperative settings and results suggest a promising alternative. Methods: The Double Sensor was placed on the forehead of patients undergoing TTM and recorded the CBT for 48 hours. The data were then compared to the temperatures measured by an esophageal thermometer. A paired t-test was used to examine possible differences between the two methods. To avoid the weaknesses of the oftenused Pearson's r, a Bland-Altman diagram, as well as the intraclass correlation coefficient (ICC) were used for this study to assess agreement and reliability of the Double Sensor. Additionally, the patients’ medication were recorded to rule out possible influence on measurements by anesthetic drugs or catecholamines. Results: From November 2015 to January 2017 data from 25 patients (M/F, median age 61 years) were recorded. The t-test showed no significant difference between the two measuring methods (t = 1.47, p = 0.14, n = 1,319). Bland-Altman results showed a mean bias of 0.02 °C (95% confidence interval 0.00 – 0.04) and 95% limits of agreement of −1.023 °C and 1.066 °C. The ICC was 0.94 (95% CI 0,93 – 0,95). The sensor caused no side effects such as rash or allergic reactions. In six patients the recorded temperatures differed from the rest of the participants. Possible explanations were a high Body-Mass-Index, prone positioning, or dislocation of the sensor during positioning of the patients. No sex-based differences could be identified. Influences on the measurements of the Double Sensor by catecholamines or sedatives administered could be ruled out. Conclusions: Measuring the CBT with a non-invasive, disposable sensor is a reliable alternative during TTM after ROSC. Integrating the sensor into other appliances such as pulse oximeters would even further increase its benefits. It is recommended to verify the results of the study with a larger patient cohort to possibly improve the limits of agreement.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Janke, David
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 8

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger, eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Janke, David. Der Hitzeflusssensor als vielversprechende Alternative zur Messung der Körperkerntemperatur während des zielgerichteten Temperaturmanagements. 2022. https://doi.org/10.17169/refubium-35596