Genauigkeit der Implantatinsertion mithilfe additiv gefertigter Bohrschablonen aus Biopolymeren

Abstract

dc:description.abstract

Introduction: Digital implant planning enables precise prosthetically-driven implant positioning using surgical guides. Surgical guides are most likely to be additively manufactured from a photopolymerizable resin und use metal sleeves for drill guidance. The production is cost intensive and the biocompatibility of resins is controversially discussed. Sleeveless surgical guides made out of polylactic acid (PLA) might represent an alternative to the current gold standard. PLA is more economic, made out of renewable resources and is thus more environmentally friendly. Due to the biocompatibility of the material, metal sleeves could possibly be dispensed with. The aim of this study is to compare surgical guides from "Fused Filament Fabrication" (FFF) using PLA and "Stereolithography" (SLA) using resin with regard to the implant accuracy. Furthermore, potential effects of additionally inserted guide sleeves and the impact of the implant region was assessed. Methods: A planning software was used to design a surgical guide with (H) and without (OH) metal sleeves for the placement of two implants in a mandibular resin model in the region of the second premolar and molar. Each dataset was additively manufactured by SLA or FFF, yielding four groups (SLA-H, SLA-OH, FFF-H, FFF OH). After sterilizing the surgical guides of each group (n=10) a series of 80 two-piece titanium implants were placed in the mandibular model. Scan bodies were screwed on the implants and digitized using a desktop scanner. Horizontal and vertical deviations were evaluated at the apex and shoulder level, as well as main axis aberration. Regarding the statistical analysis a one way MANOVA with post-hoc Tukey-HSD was performed. Results: Guided implant insertion resulted in a maximum lateral deviation of 0.97 mm at the apex and 0.55 mm at the shoulder. Vertical deviations with a maximum of 0.56 mm at the apex and 0.24 mm at the implant shoulder were measured. Maximum axial deviation did not exceed 3.02°. Between all groups, no statistically significant difference regarding the vertical position of the implant was found (p ≤ .054). For sagittal deviations at the implant shoulder FFF-groups showed higher deviations (p ≤ .033) to SLA-groups, though no differences in the transversal dimension was measured (p ≤ .054). Insertion of a metal sleeve had no significant effect on sagittal, vertical or axial accuracy but resulted in increased transversal deviations (p = .001). Conclusion: Within the limits of this in-vitro setup, all inserted implants obtained maximum deviations of less than 1 mm, both laterally and vertically, and might therefore be acknowledged suitable for clinical application. PLA showed no significant difference in terms of implant accuracy compared to the gold standard SLA. The insertion of metal sleeves did not improve the accuracy of the implant surgery in-vitro. The experimentally used biopolymer-based PLA guides were cheaper to produce, time-effective, and potentially biodegradable.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hromadnik, Valentin
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 6

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-36012-0

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hromadnik, Valentin. Genauigkeit der Implantatinsertion mithilfe additiv gefertigter Bohrschablonen aus Biopolymeren. 2022. https://refubium.fu-berlin.de/handle/fub188/36012