Back to search

Freie Universität Berlin

Computed tomography aortic valve calcium scoring and its association with adverse events following transcatheter aortic valve implantation (TAVI)

Abstract

dc:description.abstract

Background: Severe aortic valve calcification (AVC) has generally been recognized as a key factor in the occurrence of adverse events after transcatheter aortic valve implantation (TAVI). To date, however, a consensus on a standardized calcium detection threshold for aortic valve calcium quantification in contrast-enhanced computed tomography angiography (CTA) is still lacking. The present thesis aimed at comparing two different approaches for quantifying AVC in CTA scans based on their predictive power for adverse events and survival after a TAVI procedure. Methods: The extensive dataset of this study included 198 characteristics for each of the 965 prospectively included patients who had undergone TAVI between November 2012 and December 2019 at the German Heart Center Berlin (DHZB). AVC quantification in CTA scans was performed at a fixed Hounsfield Unit (HU) threshold of 850 HU (HU 850 approach) and at a patient-specific threshold, where the HU threshold was set by multiplying the mean luminal attenuation of the ascending aorta by 2 (+100 % HUAorta approach). The primary endpoint of this study consisted of a combination of post-TAVI outcomes (paravalvular leak ≥ mild, implant-related conduction disturbances, 30-day mortality, post-procedural stroke, annulus rupture, and device migration). The Akaike information criterion was used to select variables for the multivariable regression model. Multivariable analysis was carried out to determine the predictive power of the investigated approaches. Results: Multivariable analyses showed that a fixed threshold of 850 HU (calcium volume cut-off 146 mm3) was unable to predict the composite clinical endpoint post-TAVI (OR=1.13, 95 % CI 0.87 to 1.48, p=0.35). In contrast, the +100 % HUAorta approach (calcium volume cut-off 1421 mm3) enabled independent prediction of the composite clinical endpoint post-TAVI (OR=2, 95 % CI 1.52 to 2.64, p=9.2x10-7). No significant difference in the Kaplan-Meier survival analysis was observed for either of the approaches. Conclusions: The patient-specific calcium detection threshold +100 % HUAorta is more predictive of post-TAVI adverse events included in the combined clinical endpoint than the fixed HU 850 approach. For the +100 % HUAorta approach, a calcium volume cut-off of 1421 mm3 of the aortic valve had the highest predictive value.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Leibfried, Philipp
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-37587-8

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Leibfried, Philipp. Computed tomography aortic valve calcium scoring and its association with adverse events following transcatheter aortic valve implantation (TAVI). 2023. https://refubium.fu-berlin.de/handle/fub188/37587