Comparison of separate measurement procedures for determination of GFR in chronic kidney disease
Abstract
dc:description.abstractBackground: Accurate and precise measurement of glomerular filtration rate (GFR) is important for the diagnosis and stratification of chronic kidney disease (CKD). Iohexol is a widely accepted exogenous marker to measure GFR. High-performance liquid chromatography (HPLC) and ultra-high-performance liquid chromatography (UPLC) are the most commonly used methods for measuring iohexol concentration. However, there is limited research on the HPLC and UPLC methods and studies comparing the two. Therefore, this study fills this gap by comparing the two above-mentioned methods for measuring iohexol concentration to identify the differences, if any, in the results produced by the two. In addition, the samples were measured by Berlin Initiative Study (BIS) ten years ago; the same samples were re-measured to investigate if there are differences between long-term and short-term stored samples. Method: Serum sample iohexol concentrations were measured using both HPLC and UPLC. Iohexol serum concentrations and iohexol-derived mGFR of 56 patients (386 serum samples) were compared. Since the data was measured ten years ago as part of the BIS study (HPLC_BIS measurement), the same samples were re-measured using HPLC for this study (HPLC measurement), and the differences between the results produced by the two were compared. Result: When comparing HPLC and UPLC, Passing-Bablok regression revealed y = −1.02 x - 1.11 (slope 95% CI: 1.01, 1.04; Y-intercept 95% CI: −2.50, 0.04 µg/ml). Lin’s concordance correlation coefficient (CCC) showed almost perfect agreement (ρ>0.99). Bland-Altman analysis illustrated a mean bias of 1.70%. For iohexol-derived GFR results, Passing-Bablok regression illustrated a slope value of 1.00 (95% CI: 0.94, 1.04), and an intercept value of 0.28 ml/min/1.73m2 (95% CI: −3.05 - 3.96 ml/min/1.73m2). CCC indicated that the agreement was substantial (ρ = 0.97). The Bland-Altman analysis demonstrated a mean bias of 1.66%. When comparing HPLC and HPLC_BIS, Passing-Bablok regression line demonstrated y = 0.95 x -1.10 (slope 95% CI: 0.94, 0.97; intercept 95% CI: −2.32, 0.22 µg/ml). CCC indicated substantial agreement (ρ = 0.97). The Bland-Altman plot showed a mean bias of 5.93%. For iohexol-derived GFR results, Passing-Bablok regression showed an intercept value of 2.07 ml/min/1.73m2 (95% CI: −1.32, 6.20 ml/min/1.73m2) and a slope value of 1.03 (95% CI: 0.97, 1.09). CCC revealed substantial agreement (ρ = 0.97). The Bland-Altman analysis showed a mean bias of 5.62%. Conclusion: This study found no significant difference or bias in the quantification of iohexol concentration and iohexol-derived GFR between either the HPLC method and the UPLC method or between long-term and short-term stored samples.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hu, Nana
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 5Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-37899-4
- Identifier URI
- http://dx.doi.org/10.17169/refubium-37615