Back to search

Freie Universität Berlin

Functional heart valve stent designs for future transcatheter autologous pulmonary valve replacement

Abstract

dc:description.abstract

Background Transcatheter pulmonary valve replacement (TPVR) has asserted its position as a cornerstone in cardiology and become a nonsurgical alternative for patients with a dysfunctional right ventricular outflow tract (RVOT), demonstrating excellent early and late clinical outcomes. Short- and long-term complications of TPVR include stent fracture and migration, coronary compression, and valve regurgitation. Objective The purpose of this study is to describe methodology for developing Nitinol stents by conducting a computational design and finite element analysis in conjunction with 3D reconstruction of animal cardiac CT for TPVR. Methods 3D cardiac CT reconstruction was achieved using 3D Slicer, from which the RVOT + pulmonary artery (PA) was exported for blood flow simulation and hoop force acquisition with the stents. Functional stents were designed using Autodesk Fusion 360 and divided into three morphological geometries: group 1–straight tubular stents, group 2–corollaceous stents, and group 3–corollaceous stents with an elliptic geometry. Stent simulations for stent life and radial force, and the hoop force of the stent during expansion with the RVOT+PA model were obtained in Ansys. The blood flow simulation of RVOT+PA was performed using Ansys with the velocity-based coupled solver. Results 3D cardiac CT reconstructions were obtained in STL format, from which the right ventricle (RV) +PA model was performed for the blood flow simulation and the hoop force was obtained with the stents. Twelve functional stents were successfully designed and exported in SAT and STP formats for simulation. All stent life (Times)/radial force (N) were achieved: Group 1 comprised the stents DGS 3 (3219.2/1.88E+05), DGS 5 (16406/1.94E+05), DGS 7 (1.00E+06/1.89E+05), DGS 8B (0/3.74E+05), DGS-10B (8370.1/2.41E+05), DGS 12D (1.00E+06/2.41E+08); Group 2 comprised the stents DGS 8A (0/3.60E+05), DGS 9A (0/3.60E+05), DGS 10A (46093/2.28E+05), DGS 12C (2.50E+005/1.69E+05); Group 3 comprised the stents DGS 12A (1.00E+06/2.38E+08), DGS 12B (54509/2.20E+05). Hoop force (N) was obtained from the 12 stents: Group 1–DGS 5 (57802), DGS 7 (54647), DGS 8B (53248), DGS 10B (56650), DGS 12D (46297). Group 2–DGS 8A (50490), DGS 9A (60393), DGS 10A (23639), DGS 12C (29802). Group 3–DGS 12A (16368), DGS 12B (16368). The RV+PA blood flow simulation demonstrated that the anterior part of the PA wall had the largest shear force. Conclusions DGS 12C, DGS 12D, DGS 10A, DGS 10B, DGS 7, and DGS 5 can be subsequently tested in vitro. Autologous pulmonary valves could be sutured onto the functional stents to maintain their original geometry prior to implantation. Pre-implantation 3D CT reconstruction and stent simulation can be performed for better evaluation and visualization. The RV+PA blood flow simulation may serve as a significant input for the design of stents and pulmonary valve to determine the shear force throughout the cardiac cycle.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sun, Xiaolin
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sun, Xiaolin. Functional heart valve stent designs for future transcatheter autologous pulmonary valve replacement. 2023. https://doi.org/10.17169/refubium-38740