Back to search

Freie Universität Berlin

Modeling photon transport and reconstruction of optical properties for performance assessment of laser and fluorescence mammographs and analysis of clinical data

Abstract

dc:description.abstract

It was the aim of the present thesis to develop and validate statistical and numerical methods as well as software tools necessary to quantitatively assess various instrumental concepts, measurement schemes and methods of data analysis for optical and fluorescence mammography, including analysis of clinical data. To this end, a software suite was developed based on the finite element method (FEM) to simulate propagation of NIR (laser) light and fluorescence radiation through inhomogeneous turbid media based on the diffusion approximation of the radiative transfer equation and to carry out linear and nonlinear reconstructions of the absorption and scattering properties of the medium from simulated or experimental data taken in frequency domain or time-domain. Simulations of photon densities of diffusely transmitted or remitted laser radiation and fluorescence radiation from an exogenous fluorescent contrast agent are supported by the software package for arbitrary object (breast) geometries and arrangements of sources and detectors. In this thesis, a statistical method was developed to quantitatively assess detection limits for a lesion achieved by the two instrumental concepts implemented in optical mammographs that are presently used in clinical trials of laser and fluorescence mammography. Tomographic instrumentation require the patient to lie in prone position with one of her breasts immersed in a cup-shaped measurement chamber filled with scattering liquid (tomographic geometry) and equipped with a large number of light sources and photon detectors at its surface. Transmittance of laser and fluorescence radiation is measured for a large number of source-detector combinations amounting to essentially complete angular sampling. Scanning mammographs, on the other hand, slightly compress the breast between two parallel glass plates (slab geometry) and scan the source across one compression plate, taking transmittance measurements at a large number of source positions yet at only a limited number of source-detector offsets (limited angular sampling). The statistical analysis of noisy simulated photon densities of diffusely transmitted laser and fluorescence radiation is based on a chi-square test (test of null hypothesis) and allows to quantitatively determine the minimal size (radius) of a single (spherical) heterogeneity for it to be detectable at assumed absorption and fluorescence contrast with respect to the (homogeneous) background medium. For this purpose, numerical breast models were developed with estimated breast shapes consistent with the particular measurement geometry and covering a realistic range of tissue absorption and scattering properties, i.e. of light attenuation. From measurements carried out with existing tomographic instrumentation, a realistic noise model was derived to determine absolute and relative noise contributions to simulated photon densities of transmitted laser and fluorescence radiation. From the statistical analysis, the minimal detectable size of a (spherical) lesion was determined at each position inside the breast, depending on breast (cup) size (tomographic geometry) and thickness of the compressed breast (slab geometry) as well as on background tissue optical properties. In addition, it was studied how lesion detectability depends on breast compression (slab geometry), on absolute and relative noise of simulated photon densities, on lesion size and on fluorescence contrast of the lesion. Because of the generally smaller source-detector distances associated with the compressed breast geometry, and hence higher transmitted laser and fluorescence intensities, lesion detection sensitivities are generally higher for scanning compared to tomographic mammographs and are less affected by the absolute noise floor. A minimal fluorescence contrast of 2.5 : 1 of the lesion above a homogeneous background was estimated for it to be detectable in fluorescence mammograms. Although such investigations could also be carried out by reconstructing absorption coefficients and the concentration of the exogenous fluorescent dye to generate optical mammograms, the excessive computational efforts required would prevent such systematic studies. Interpretation of time-domain projection optical mammograms (slab geometry) is feasible even without the need for reconstruction of tissue optical properties. For this purpose, a time-window analysis of temporal point spread functions of transmitted laser pulses is used as standard technique to generate projection mammograms displaying predominantly absorption and scattering properties of breast tissue. By using a numerical phantom for a tumor bearing compressed breast (slab geometry) and by simulating noisy temporal point spread functions, an improved method of data analysis of time- domain transmission mammograms was developed in this thesis that allows to reduce cross talk between absorption and scattering images compared with the standard time-window analysis. Whereas the results summarized in the preceding paragraphs were obtained from simulated data, other findings of the present thesis are based on linear and nonlinear reconstructions of tissue absorption coefficients, reduced scattering coefficients, and the concentration of an exogenous fluorescent dye. Several improvements were made on the reconstruction algorithms, e.g. introduction of a noise-weighted back projection for the algebraic reconstruction technique (ART) used to calculate the image vector, and separate regularization parameters for absorption and scattering reconstruction. Furthermore, in order to handle the amount of time- domain data that were collected by scanning mammographs (slab geometry) and to accelerate reconstructions, the standard nonlinear reconstruction technique was extended by introducing a sub-volume method. To this end, the entire (cuboid) volume of interest, where reconstructions are to be carried out, is split up into several (overlapping) cuboid sub-volumes. Likewise, the entire data set entering the reconstruction, and hence set of source-detector combinations associated with the entire volume, is divided into sub-sets of source-detector combinations adapted to each sub-volume. Subsequently, reconstructions of optical properties on the various sub-volumes are carried out in parallel, resulting in a considerable acceleration compared to the standard one-volume reconstruction method. Convergence of the standard method and of nonlinear sub-volume reconstructions was studied using simulated and experimental phantom data. Furthermore, errors and limitations introduced by the decomposition of the volume of interest into sub-volumes were investigated. Such errors can be tolerated as long as the number of sub- volumes is small and the entire data set entering the standard reconstruction is also used by the sub-volume method. In other words, the sizes of the sub- volumes must be consistent with all source-detector offsets, i.e. the data of which enter the standard nonlinear method so that no additional reduction takes place of the (limited) angular sampling range of the initial data set. The feasibility of sub-volume reconstructions using experimental phantom data was shown. The compressed breast geometry allows to record transmittance of laser and fluorescence radiation over only a restricted range of projection angles, leading to an axial resolution in reconstructed images of tissue optical properties that is even worse compared to the poor spatial resolution of tomographic mammographs. It was shown in this thesis that axial resolution of time-domain scanning mammographs (slab geometry) can be improved by using diffuse reflectance besides transmittance data. To this end, reconstructions were carried out and spatial localization was compared using simulated and experimental data including and excluding time-domain diffuse reflectance measurements. To account for the different noise levels of experimental data taken at various source-detector offsets and of data corresponding to different angular frequency components used in the reconstruction, the noise- weighted back-projection was applied, and quantitative reconstructions of fluorescent dye concentrations were carried out. Linear and nonlinear absorption reconstructions as well as (linear) fluorescence reconstructions were carried out using clinical data of four patients involved in a clinical trial on tomographic fluorescence mammography. In all cases, the lesion could be detected in absorption (reconstructed absorption coefficients, first three cases) or fluorescence (reconstructed dye concentration, forth patient) mammograms and successfully correlated with MR mammograms, whenever available. An improved initialization model was introduced for linear and nonlinear reconstructions of the clinical data, by dividing the reconstructed cup volume into two compartments, one consisting of the matching scattering liquid surrounding the immersed breast, the other compartment representing a homogeneous breast with an estimated shape and absorption and scattering optical properties that were fitted in a preprocessing step to the in vivo data taken at several optical wavelengths. Reconstructed absorption coefficients and reconstructed concentrations of the exogenous fluorescent dye used exhibited artifacts compensating for changes in scattering properties of breast tissue including lesions whereas all lesions were assumed to be pure absorbers and no variations in the reduced scattering coefficient of the tissue were taken into account.

Degree

thesis:*
Department dc:contributor.department
Physik
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ziegler, Ronny
Committee members dc:contributor.committeemember
  • Prof. Dr. H. Rinneberg
  • Prof. Dr. W. Brewer

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng, ger

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000005928-1
Dc Identifier Other
FUDISS_thesis_000000005928
FUDISS_derivate_000000004613

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ziegler, Ronny. Modeling photon transport and reconstruction of optical properties for performance assessment of laser and fluorescence mammographs and analysis of clinical data. 2008. https://refubium.fu-berlin.de/handle/fub188/3953