Back to search

Freie Universität Berlin

Quantification of structural changes in cortical bone by estimating thickness, speed of sound and pore size distribution

Abstract

dc:description.abstract

Quantitative bone ultrasound (QUS) method has been introduced as a promising alternative for diagnosing osteoporosis and assessing fracture risk. The latest QUS technologies aim to quantitatively assess structural cortical bone characteristics, e.g, cortical porosity, cortical thickness (Ct.Th) and cortical speed of sound at cortical measurement regions. Large cortical pores and reduced Ct.Th in the tibia have been proposed as an indication of reduced hip strength and structural deterioration. In this work two novel ultrasound methods were studied using a conventional ultrasound transducer to measure cortical bone properties at the tibia. The first method is a refraction and phase aberration corrected multifocus (MF) imaging approach that measures Ct.Th and the compressional sound velocity traveling in the radial bone direction (Ct.ν11). The second method is a novel cortical backscatter (CortBS) method that assesses microstructural properties in cortical bone. Both methods were validated in silico on bone models, ex vivo on bone samples and in vivo on 55 postmenopausal women at the anteromedial tibia midshaft. The aim of this work was to study the precision, accuracy, and fragility fracture discrimination performance of CortBS and MF parameters in comparison to clinical High-resolution peripheral quantitative computed tomography (HR-pQCT) and Dual-energy X-ray absorptiometry (DXA) measurements. The results of the MF approach show precise and accurate estimation of Ct.Th and Ct.ν11. The comparison of the measured Ct.Th with reference thicknesses from HR-pQCT measurement have also shown accurate determination of Ct.Th (R2=0.94, RMSE=0.17 mm). Future simulation studies with real bone structures from HR-pQCT measurements should target the validation of accurate Ct.ν11 estimation. For the first time, CortBS assessed the distribution of cortical pore size and viscoelastic properties of cortical bone in vivo. The short- term in vivo precision was observed between 1.7% and 13.9%. Fragility fracture discrimination performance was retrieved using multivariate partial least squares regression. The combination of CortBS+MF showed superior fracture discrimination performance compared with DXA and similar fracture discrimination performance compared with HR-pQCT. Further clinical studies with larger cohort size should target the potential to demonstrate the ability of CortBS and MF parameters for individual fracture risk assessment. In conclusion, alteration in cortical microstructure and viscoelasticity caused by the aging process and the progression of osteoporosis can be measured by CortBS and MF. These methods have high potential to identify patients at high risk for fragility fractures.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Nguyen-Ullrich, Minh Huong
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-39882-9

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Nguyen-Ullrich, Minh Huong. Quantification of structural changes in cortical bone by estimating thickness, speed of sound and pore size distribution. 2023. https://refubium.fu-berlin.de/handle/fub188/39882