Freie Universität Berlin
The application of 4D cardiac CT segmentation for pre-operative and post-operative transcatheter pulmonary valve replacement
Abstract
dc:description.abstractBackground: Transcatheter pulmonary valve replacement (TPVR) has become an alternative therapeutic option for patients with right ventricular outflow tract (RVOT) dysfunction. Cardiac CT angiography (CTA) is crucial for TPVR pre- and post-operative assessment of the landing zone from RVOT to pulmonary artery (PA). However, three-dimension (3D) CT is still inadequate to assess the full dynamic variation of landing zone and spatial relationships between structures over the cardiac cycle accurately. Methods: The objective of this present study was to simulate the dynamic variation of the landing zone from RVOT to PA in vivo for TPVR by four-dimension (4D) CTA segmentation and evaluate the feasibility and accuracy of the 4D straightened model. The straightened model was created by adding centerline to the right heart model, then the anatomical right heart model was straightened. The 4D conventional anatomical model and straightened model were reconstructed at 10 cardiac cycle phases in 14 cardiac CTA datasets of seven sheep underwent TPVR. The cross-sectional area, circumference, and diameter deformations over the cardiac cycle were measured at five planes of the landing zone from pre- and post-operative 4D CTA. In addition, the correlation analysis between the anatomical model and straightened model was also conducted by means of Pearson correlation and Bland-Altman analysis. Results: The clear structure of each section from RVOT to PA were observed on straightened model. Significant variations of cross-sectional area and circumference measurements showed at the RVOT plane throughout the cardiac cycle for both pre- and post-operative 4D CTA. Nevertheless, nearly no deformation of area and circumference was observed at the valvular sinuses level (Plane 3a) and the sino-tubular junction plane (Plane 4a) from pre-operative CT; the middle plane of the stent level (Plane 3b) and the top plane of the stent level (Plane 4b) from the post-operative CT. The straightened model was highly correlated with the anatomical model. The Pearson correlation coefficient between straightened model and anatomical model for cross-sectional area, circumference, minimum diameter, and maximum diameter ranged from 0.77 to 0.99 (P < 0.0001) and the limits of agreement from Bland-Altman analysis were within a good range, which further confirmed the great agreement between straightened model and anatomical model. Conclusions: The 4D CT anatomical model can be used to demonstrate the deformation of RVOT to PA dynamics over the cardiac cycle. The straightened model can show the changes in the landing area, accurately measure these data, and clearly show the structure of the various sections.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hao, Yimeng
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-40897-5
- Identifier URI
- http://dx.doi.org/10.17169/refubium-40618