Freie Universität Berlin
Evaluation of prostatic lesions by simultaneous [68Ga]Ga-PSMA-11 PET/MRI
Abstract
dc:description.abstractProstate cancer (PCa) is a malignant disease that has a negative impact on the quality of life of older men. Due to its clinical features, which include difficult detection, spread, and recurrence, the need for more accurate and better imaging diagnostic grows. In recent years, there has been a great deal of researches into multi-modality imaging, 68Ga prostate-specific membrane antigen ([68Ga]Ga-PSMA-11) positron emission tomography/ magnetic resonance imaging (PET/MRI). In terms of diagnostic accuracy, standard definition, and diagnostic stability, the existing [68Ga]Ga-PSMA-11 PET/MRI requires significant improvement. The diagnosis of prostate lesions can be optimized. The aim of this dissertation is to analyze imaging characteristics on [68Ga]Ga-PSMA-11 PET/MRI, by evaluating and quantifying lesions of PCa. This dissertation is based on four sub-projects. The research is based on retrospective study design. Multi-modality and molecular imaging techniques, [68Ga]Ga-PSMA-11 PET/MRI were applied. Scanner 3.0 T PET/MRI system (SIEMENS MAGNETOM Biograph mMR, Erlangen, Germany) was used. First, I evaluated the compatibility, consistency and diagnostic threshold SUVmax of PET and MRI in [68Ga]Ga-PSMA-11 PET/MRI. Thirty-two patients and 170 lesions were investigated in this sub-project. Second, a comparison of the diagnostic criteria of the new and old versions of Prostate Imaging Reporting and Data System (PI-RADS) was performed. Forty-six patients and 215 lesions were investigated in this sub-project. Third, the dynamic changes of dynamic contrast-enhanced (DCE)-MRI in the lesions were analyzed with quantitative analysis. Thirty-nine patients and 154 lesions were investigated in this sub-project. Fourth, radiomics analysis of PCa was studied. As it is an ongoing project, in this dissertation two cased are presented as examples. I have obtained that when the lesion-to-background ratio (LBR) is 2.5, the coincidence of the two modalities (PET and MRI) is the highest. The new version of PI-RADS offers more detailed diagnostic criteria, allowing for greater diagnostic repeatability, and the kappa value was raised from 0.723 to 0.853. DCE parameters provide more information on lesions' characteristics. It showed that the malignant lesion had more abundant blood vessels, which made the time for the contrast agent to flow into the lesion shorter than that of the benign lesion. There is also a close relationship between perfusion parameters. Radiomics analysis was presented by two cases. Diagnostic criteria improvement and lesion information refinement are beneficial in clarifying the nature of lesions, optimizing diagnostic methods, and reasonably evaluating treatment alternatives, consequently enhancing the accuracy and diagnostic efficiency of image-guided therapies.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Zhao, Jing
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-40898-2
- Identifier URI
- http://dx.doi.org/10.17169/refubium-40619