Freie Universität Berlin
Mechanical circulatory support in patients with acute cardiogenic shock
Abstract
dc:description.abstractObjectives Cardiogenic shock (CS) as the final stage of Heart failure (HF) is present in approximately 25% of cases and is associated with high mortality. Temporary mechanical circulatory support (MCS) is widely used for CS therapy. In our research, we investigated and compared different temporary MCS concepts based on microaxial intraaortic impeller pumps. Methods The data of all patients who received MCS with a temporary microaxial left ventricular impeller pump in the German Heart Center Berlin (DHZB) since 01/2016 were collected retrospectively and used for a database establishment. The obtained data were analyzed in regard to different clinical aspects and published. This dissertation summarizes and describes the results of three major publications. Results The results of the pilot study demonstrated a 43% survival in 28 patients on isolated impeller pump support, as well as 44% in 9 CS patients on combination of v a ECLS and Impella. Preoperative cardiopulmonary resuscitation (CPR) and an arterial pH <7.2 or >7.45 were associated with poor outcomes. In the second study, 70 patients were supported with Impella 5.0/5.5®. The overall 30 day survival was 51%. An increase in arterial lactate (OR 1.217 per 1 mmol/L; p=0.015) and CPR before implantation (OR 16.74; p=0.009) were identified as predictors of 30 day mortality on Impella support. A cut-off of 8 mmol/L for preoperative lactate showed a specificity of 0.944 and a sensitivity of 0.294 (OR 7.083, CI 1.422 35.28; p=0.017) for 30 day mortality. Based on these data, an algorithm for optimal short-term MCS therapy was developed and thereafter applied as a standardized operational procedure at the DHZB. In my third analysis we compared the percutaneously implanted Impella CP® and larger surgical Impella 5.0/5.5®. In unadjusted cohorts the 30 day survival was significantly higher in the Impella 5.0/5.5® group (58% vs. 36%, p=0.021). After propensity score adjustment for relevant preoperative demographic and hemodynamic parameters, the 30 day survival was similar between the groups (OR 1.23, 95% CI [0.34-4.18], p=0.744). Preoperative lactate levels above 8 mmol/L and CPR before implantation were associated with poor outcomes in both cohorts (OR 10.7, 95% CI [3.45-47.34], p<0.001; OR 13.2, 95% CI [4.28-57.89], p<0.001). Based on these results the selection algorithm from the second study was amended to include the use of percutaneous impeller pumps. Conclusions A total of 203 patients treated with different MCS devices were analyzed. Our studies demonstrated that temporary MCS with microaxial impeller pumps is a feasible treatment in CS patients. In cases with preoperative CPR or lactate levels ≥ 8 mmol/L an advanced treatment concept with a combination of Impella and v a ECLS should be pursued. An algorithm based on these parameters may prove useful for optimal patient selection and to identify optimal temporary MCS in CS patients.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2023
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Nersesian, Gaik
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 3Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier URI
- https://refubium.fu-berlin.de/handle/fub188/41078