Back to search

Freie Universität Berlin

New developments in giant intracranial aneurysm diagnostics

Abstract

dc:description.abstract

Background: Giant intracranial aneurysms (GIA) differ substantially from smaller IA not only concerning their management but also concerning their diagnostics. The main objective of the studies summarized below is to develop and compare new diagnostic and monitoring techniques in GIA using magnet resonance imaging (MRI). In particular, we describe different modes of GIA quantification and the occurrence of perianeurysmal edema (PAE) and partial thrombosis (PT). In addition, we aim to delineate changes in GIA volume and mass effect on the brain after surgical GIA treatment that is not directed at immediate aneurysm occlusion. Methods: MRIs of 69 GIA were retrospectively analyzed regarding GIA location, diameter and volume as well as the occurrence and volume of PAE and PT. Furthermore, the clinical impact of these parameters was evaluated. In a second step, we measured changes in GIA volume, lateral ventricle volume (LVV) and mid-line shift (MLS) by using pre- and postoperative MRIs of 19 anterior circulation GIA. Results: Comparing GIA sizes produced different results depending on whether GIA diameter or volume was measured. A correlation between these two modes of measurement was only observed in anterior circulation GIA. Only GIA location but not GIA size correlated with the patient's clinical condition. PAE was observed only in one third of all cases. Both GIA volume and PT were associated with the occurrence and size of PAE. Our cohort of 19 anterior circulation GIA showed a significant decrease in postoperative GIA volume as well as an increase in LVV and a reduction in MLS. The decrease in GIA volume correlated with the increase in ipsilateral LVV but not with the change in MLS. Conclusion: Our data suggest that GIA size is clinically less relevant than examining GIA location, shape and mass effect. However, GIA volume as well as PT have a distinct influence on the occurrence of PAE. Since cavernous ICA aneurysms showed no PAE at all one may speculate that the dura mater could serve as a barrier protecting the brain from PAE formation. We showed that indirect surgical GIA therapy leads to a significant decrease in postoperative GIA volume and mass effect exerted on the brain.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Maldaner, Nicolai
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-fudissthesis000000103137-6
Dc Identifier Other
FUDISS_thesis_000000103137
FUDISS_derivate_000000020095

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Maldaner, Nicolai. New developments in giant intracranial aneurysm diagnostics. 2017. https://refubium.fu-berlin.de/handle/fub188/4138