Back to search

Freie Universität Berlin

How short can we go? The impact of BOLD delay scan length on detecting hypoperfusion

Abstract

dc:description.abstract

Background: Noninvasively detecting hypoperfusion using blood oxygen level dependent (BOLD) delay is a relatively new method. Previous BOLD delay studies used longer scans than typical of established perfusion imaging methods. The effect of shortening these scans is not yet known. Here, we systematically evaluated the impact of scan length on brain perfusion assessment with BOLD delay. Method: Sixty-three acute stroke patients underwent a standard stroke imaging protocol including multiband EPI scans for BOLD delay mapping (CMRR, TR/TE=400/30 ms, flip angle 43°, multiband factor=6, thirty 4.0-mm slices, acquisition time: 340s). To reflect a representative clinical population, patients were not excluded based on head motion. A subset of 43 patients with visible hypoperfusion on BOLD delay maps were selected for quantitative analysis. Resting state functional MRI (rsfMRI) data of 63 patients with acute ischemic stroke were divided into 5 progressively shortened scan segments. The quality and diagnostic utility of the BOLD delay maps generated by each segment were assessed by two readers. Binary logistic and ordinal mixed effects models were executed for the qualitative comparison of shorter scans with the full-length scan. We also analyzed the effect of scan length on the hypoperfusion lesion volumes using Bland-Altman plot and linear mixed effects models for the quantitative volumetric analysis of the subset group. Head motion was always accounted for in the mixed effects models. 7 Results: Binary logistic and ordinal mixed effects models showed that shortening the scan length by 60% diminished the quality of the maps (OR 0.3 [0.2, 0.46]) and their sensitivity to hypoperfusion detection (OR 0.33 [0.18, 0.59]) drastically. However, linear mixed effects models revealed that various scan segments were not systematically associated with volumetric estimation of lesions. Head motion adversely altered noise and structure clarity on the BOLD delay maps. Discussion: This study methodically assessed the effect of scan time reduction on the diagnostic quality of BOLD delay perfusion mapping in acute stroke. For assessment of perfusion using BOLD delay, scan time can be reduced to 3 min 24 sec without a significant loss of diagnostic accuracy and image quality. Hypoperfusion lesion volume estimates were robust down to 1 min 8 sec scan time. Our results provide an important step towards the implementation of contrast agent-free BOLD delay mapping for detecting hypoperfusion.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tanritanir, Ayse Ceren
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 5

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-41582-3

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Tanritanir, Ayse Ceren. How short can we go? The impact of BOLD delay scan length on detecting hypoperfusion. 2024. https://refubium.fu-berlin.de/handle/fub188/41582