Back to search

Freie Universität Berlin

MRT Sicherheit von Patienten mit kürzlich implantierten Koronarstents in Bezug auf kardiale Ereignisse und Re-Okklusionsstörungen bei verschiedenen Feldstärken

Abstract

dc:description.abstract

Background: Stent-implantation is often used by treating coronary heart disease (CHD). Because of ferromagnetic characteristics of stents, stent developers suggest not to undergo MRI shortly after stent-implantation. Our first aim was to review current literature, regarding the influence of performing MRI shortly after stent-implantation on re-occlusion rates. Our second aim was to proof, if MRI can be safely performed in patients independent from field strength (1.5 Tesla versus 3.0 Tesla). Methods: We focused on representative studies in MEDLINE database. Included were clinical studies with focus on MRI safety within 8 weeks after stent-implantation. Aim of the studies was to record cardiac events in a follow up post MRI. Also included were in- vitro studies, which investigated the effects of magnetic fields on the stents. Moreover we used the German Heart Center database to analyze catheterization examinations of 44 patients before and after MRI. To investigate influence of MRI on re-occlusion we analyzed coronary diameter stenosis (CDS) and plaque volume (PV) before and after MRI and compared them to current literature for patients not undergoing MRI. MRI was performed in a time interval of about 8 weeks after stent-implantation. Results: Our search resulted in 17 publications. Clinical studies differenced in patients with acute cardiac event and with stable CHD. MRI was performed by different field strengths (1.5 Tesla/3.0 Tesla) and stent types (bare metal stents (BMS)/drug eluting stents (DES)). None of the studies showed a negative influence on the incidence of cardiac events. In-vitro studies showed only minimal or no influence of MRI on the stents. Concerning data of German Heart Center, CDS at follow up was significantly increased compared to baseline (p<0.001). Incidence of cardiac events was higher C. D. Schenk 13 than in reference literature. PV at follow up was not only significantly increased, but also lower than baseline (p=0.230). However, the difference between the measurements of CDS and PV did not differ significantly to reference literature. Conclusion: Current literature showed no increased rate of cardiac events for patients undergoing MRI within 8 weeks after stent placement. This was independent of used field strength, stent type, or if patients had an acute cardiac event or a stable CHD. Although, regarding data of German Heart Center, change in CDS and incidence of cardiac events were higher, this could be explained by the higher morbidity and risk profile of our patients in comparison to patients in reference literature. Moreover, change in PV was lower than in reference literature. Together with the findings of all studies, we can underline the current tendency, performing MRI in patients shortly after stent- implantation seems to be safe.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schenk, Christian David
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 6

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
ger

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-42499-3

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Schenk, Christian David. MRT Sicherheit von Patienten mit kürzlich implantierten Koronarstents in Bezug auf kardiale Ereignisse und Re-Okklusionsstörungen bei verschiedenen Feldstärken. 2024. https://refubium.fu-berlin.de/handle/fub188/42499