Back to search

Freie Universität Berlin

A Multilevel Reader Comparison Software Tool for Semi-Automated Quality Control in Cardiovascular Magnetic Resonance Imaging: Lazy Luna

Abstract

dc:description.abstract

Cardiovascular magnetic resonance imaging (CMR) provides a non-invasive and detailed assessment of cardiac structures and tissues, offering valuable quantitative assessments for diverse cardiac conditions. Quantification requires precise annotations by readers, including reference points and delineations of heart chambers, myocardium and other structures. As clinical applications multiply and readers are supported by the clinical integration of artificial intelligences (AI), evaluating the reproducibility of readers and quantification methods becomes essential. The aim on this thesis is to design, implement and test an extendible software tool, Lazy Luna (LL), that is dedicated to semi-automated multilevel reader comparison to increase quality control in CMR. A multilevel comparison of readers offers annotation comparisons, quantitative clinical parameter (CP) comparisons, and causal explanations for CP differences with annotation differences. First, a software prototype was designed and implemented for short-axis (SAX) cine imaging. Annotations were modelled as geometric objects, ensuring exact calculations of segmentation metric values and CPs. Difference tracing was implemented to allow for finding causal annotation explanations for CP differences between readers. A graphical user interface (GUI) was implemented to enable user-inspection of statistical reader differences and locating their origins in annotations. LL was tested by comparing two CMR experts to each other who annotated 13 SAX cine datasets. Second, interfaces were implemented for all software components (e.g. CPs, visualizations, tables) to facilitate the extendibility of LL to new imaging sequences. The extendibility was tested by applying LL to 13 parametric T1 mapping cases annotated by two expert readers and Late Gadolinium Enhancement (LGE) cases from the openly available Emidec dataset with reference contours and AI contours. First, the software prototype of LL calculated precise segmentation metrics and CPs. The GUI allowed for tracing large CP differences to contouring differences. The SAX reader comparison revealed that differences in basal slices contour choices led to large volumetric differences. Second, the extendible back- and frontend of LL allowed for extensions to T1 mapping and LGE. For T1 mapping LL was used to trace CP differences to contouring variability. For LGE LL revealed an undertrained AI that had learned the myocardial contour, but poorly estimated scar tissue. The application cases showed that LL is useful open-source software for reader comparison on multiple imaging techniques. The semi-automated multilevel reader comparison software, Lazy Luna, was successfully implemented for several CMR imaging techniques. LL calculates differences for large cohorts and offers qualitative explanations for biases between readers. LL provides insights into the challenges of CMR standardization and promising technologies for the future of quantitative CMR.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hadler, Thomas
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 6

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-43937-2

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hadler, Thomas. A Multilevel Reader Comparison Software Tool for Semi-Automated Quality Control in Cardiovascular Magnetic Resonance Imaging: Lazy Luna. 2024. https://refubium.fu-berlin.de/handle/fub188/43937