Back to search

Freie Universität Berlin

Harmonization of confounding parameters to minimize induced biases on parametric T1 maps in cardiovascular magnetic resonance imaging

Abstract

dc:description.abstract

Background Parametric T1 mapping is a quantitative method for myocardial tissue differentiation in cardiovascular magnetic resonance (CMR) that lacks comparability due to missing universal valid reference values. Confounding parameters (CP) impairing the myocardial T1 value quantification are described in literature. These CPs originates from subject, technologic and post-processing specific variations. The aim of this work was the evaluation of a post-hoc standardization approach for native parametric T1 maps within the self-developed Magnetic Resonance Imaging Software for Standardization (MARIS-SA). As quantitative measurements require a segmentation of the region of interest (ROI), a novel cascaded segmentation (CASEG) approach is additionally introduced as a necessary pre-processing step for MARISSA. Methods The proposed CASEG consisted of a bounding box (BB) prediction followed by a segmentation model. The BB was enlarged by a magnification factor of 1.5 to assure for full left ventricular coverage. Three CASEG pipelines were tested against a reference U-Net (refU): cropU, which used the enlarged BB image section, crinU, which used the enlarged image section and the original BB mask and cropU_A, which used the BB image section of a direct enlarged BB predictor. All models shared the same hyperparameters and were tested with respect to geometric and quantitative outcomes. The dataset included 403 subjects with 1080 native and 358 post-contrast T1 maps that were split into 75% training, 10% validation and 15% test data. In MARISSA 214 healthy subjects (814 T1 maps) were used for training standardization models with respect to the CPs age, sex, scanner and sequence. Among the training dataset both sex, eleven scanners, eight sequences and an age distribution of 38±15years were available. Five adjustable standardization pipeline settings were optimized among 240 tested combinations by minimizing the coefficient of variation (COV) in a cohort of 40 healthy subjects (HTE, 156 T1 maps). The evaluated best per-forming standardization pipeline (BPSP) was then compared to 112 patients with a hypertrophic cardiomyopathy (HCM, 121 T1 maps) and 24 patients with an amyloidosis (AMY, 24 T1 maps). Results The Dice Similarity Coefficient as a measure of the geometric domain improved significantly for the test data in cropU, crinU and cropU_A (all around 80%) compared to refU (around 70%) while the mean absolute error improved only slightly without significance. The cropU represented the base segmentation in MARISSA. The BPSP halved the COV in the HTE to 6% while reaching a diagnostic sensitivity and specificity of 96%/92% between HTE and AMY, 72%/72% between HTE and HCM, and 88%/98% between HCM and AMY. Conclusion CASEG significantly improved the automatic segmentation in the geometric but not in the quantitative domain. MARISSA harmonized parametric T1 mapping values while maintaining the diagnostic accuracy for two dedicated patient groups.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Viezzer, Darian Steven
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 4

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-45259-4

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Viezzer, Darian Steven. Harmonization of confounding parameters to minimize induced biases on parametric T1 maps in cardiovascular magnetic resonance imaging. 2025. https://refubium.fu-berlin.de/handle/fub188/45259