Freie Universität Berlin
Harmonization of confounding parameters to minimize induced biases on parametric T1 maps in cardiovascular magnetic resonance imaging
Abstract
dc:description.abstractBackground Parametric T1 mapping is a quantitative method for myocardial tissue differentiation in cardiovascular magnetic resonance (CMR) that lacks comparability due to missing universal valid reference values. Confounding parameters (CP) impairing the myocardial T1 value quantification are described in literature. These CPs originates from subject, technologic and post-processing specific variations. The aim of this work was the evaluation of a post-hoc standardization approach for native parametric T1 maps within the self-developed Magnetic Resonance Imaging Software for Standardization (MARIS-SA). As quantitative measurements require a segmentation of the region of interest (ROI), a novel cascaded segmentation (CASEG) approach is additionally introduced as a necessary pre-processing step for MARISSA. Methods The proposed CASEG consisted of a bounding box (BB) prediction followed by a segmentation model. The BB was enlarged by a magnification factor of 1.5 to assure for full left ventricular coverage. Three CASEG pipelines were tested against a reference U-Net (refU): cropU, which used the enlarged BB image section, crinU, which used the enlarged image section and the original BB mask and cropU_A, which used the BB image section of a direct enlarged BB predictor. All models shared the same hyperparameters and were tested with respect to geometric and quantitative outcomes. The dataset included 403 subjects with 1080 native and 358 post-contrast T1 maps that were split into 75% training, 10% validation and 15% test data. In MARISSA 214 healthy subjects (814 T1 maps) were used for training standardization models with respect to the CPs age, sex, scanner and sequence. Among the training dataset both sex, eleven scanners, eight sequences and an age distribution of 38±15years were available. Five adjustable standardization pipeline settings were optimized among 240 tested combinations by minimizing the coefficient of variation (COV) in a cohort of 40 healthy subjects (HTE, 156 T1 maps). The evaluated best per-forming standardization pipeline (BPSP) was then compared to 112 patients with a hypertrophic cardiomyopathy (HCM, 121 T1 maps) and 24 patients with an amyloidosis (AMY, 24 T1 maps). Results The Dice Similarity Coefficient as a measure of the geometric domain improved significantly for the test data in cropU, crinU and cropU_A (all around 80%) compared to refU (around 70%) while the mean absolute error improved only slightly without significance. The cropU represented the base segmentation in MARISSA. The BPSP halved the COV in the HTE to 6% while reaching a diagnostic sensitivity and specificity of 96%/92% between HTE and AMY, 72%/72% between HTE and HCM, and 88%/98% between HCM and AMY. Conclusion CASEG significantly improved the automatic segmentation in the geometric but not in the quantitative domain. MARISSA harmonized parametric T1 mapping values while maintaining the diagnostic accuracy for two dedicated patient groups.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Viezzer, Darian Steven
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-45259-4
- Identifier URI
- http://dx.doi.org/10.17169/refubium-44971