Back to search

Freie Universität Berlin

Evaluation of optimum processing parameters for joining different dental PEEK grades via ultrasonic welding

Abstract

dc:description.abstract

Objectives: The experiment was designed to determine a viable process to permanent-ly bond different PEEK grades used for dental applications such as frameworks of re-movable partial dentures (RPDs). For this purpose, ultrasonic welding (UW) could have a great potential due to the thermoplastic nature of PEEK compounds. Therefore, this study aimed to investigate the feasibility of welding dental PEEK grades using an UW device and determine the optimum welding conditions. Methods: This research was carried out in different stages to analyze welding modes, relationships between different process parameters, and the minimum values needed to create a weld. In the first step, rectangular plates from three different dental PEEK compounds (un-filled, white, and red colored) were welded using four different parameter settings of the microprocessor-controlled ultrasonic welder. For each mode, a combination of pre-set welding parameters and the feedback provided by the ultrasonic welder was rec-orded. Additionally, the effect of various factors on the welding quality has been evaluated, such as sonotrode geometry and the surface roughness of the samples to be welded. As a final step, the possibility of assembling PEEK plates of the exact geometry of ac-tual dental PEEK prosthesis combining different PEEK compounds has been carried out. Therefore, an energy-controlled welding mode was selected to ultrasonically weld at four different welding energies. The shear bond strength (SBS) of the joints has been measured, and the mechanisms of the shear fracture have been analyzed by visual and microscope observations of the fractured surfaces. Results: The welding energy was the parameter with the highest impact on the weld-ing of PEEK samples, followed by the amplitude of vibrations. The highest bond strength of 16.37 ± 1.69 MPa was obtained with a combination of 90 Ws welding ener-gy and 70 % amplitude. As a result of the sever indentation and perforation caused by the sonotrode, the lowest bond strength was obtained with welding energy of 130 Ws. Conclusions: The optimal parameter combination to ultrasonically weld samples with the dimensions of an RPD made of PEEK included an energy of 90 Ws 70 % ampli-tude, a load of 29, 42 N for 31 ms using a sonotrode with a waffle pattern on a surface area of 4 x 4 mm.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Abdulfattah Abdelkader Mohamed, Nesreen
Committee members dc:contributor.committeemember
  • N.N.
  • N.N

Subjects

dc:subject × 2

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*
URN
urn:nbn:de:kobv:188-refubium-46210-6

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Abdulfattah Abdelkader Mohamed, Nesreen. Evaluation of optimum processing parameters for joining different dental PEEK grades via ultrasonic welding. 2025. https://refubium.fu-berlin.de/handle/fub188/46210