Freie Universität Berlin
Oberflächen-EMG kann zur Erkennung patienteneigener Atemaktivität im schweren ARDS gleichwertig mit dem Goldstandard der Ösophagusdruckmessung eingesetzt werden
Abstract
dc:description.abstractMechanical ventilation in intensive care is primarily a lifesaving therapy. Nevertheless, it carries risks.It has been shown that excessive, but also insufficient support from the ventilator can lead to diaphragmatic atrophy and asynchrony, which in turn are associated with increased mortality. Thus, ventilator settings should be adjusted to the patient's spontaneous breathing comfort to achieve an appropriate division of work of breathing between patient and ventilator and to accelerate successful weaning from mechanical ventilation. The current gold standard for the quantification of spontaneous respiratory activity is the determination of esophageal pressure using an esophageal balloon catheter, which, however, is still not used regularly and comprehensively due to practical disadvantages and its invasiveness. An alternative is sEMG measurement on respiratory muscles, which was compared with the previous gold standard in this study. Parallel measurement of sEMG and esophageal pressure was performed on 37 ventilated patients at three different measurement times with increasing spontaneous respiratory activity during their intensive care unit stay. In the data obtained, the onset of breaths with increased respiratory muscle activity was time-marked in both sEMG and esophageal pressure measurements by two analysts blinded to each other. This allowed 5120 individual breaths to be identified and compared. To be comparable to the Pes measurement, the temporal markers of the sEMG signal should be comparable in sensitivity and specificity to those of the esophageal pressure. The sEMG measurement is superior to the Pes measurement in both respects. Regular breaths with increased respiratory muscle activity could be identified in the sEMG measurement. This identification is not dependent on the examiner and is more accurate in terms of time than in Pes measurements. Thus, sEMG measurement can be used to determine spontaneous respiratory muscle activity as an alternative to esophageal pressure measurement. The new measurement method should also be superior to the previous gold standard in everyday clinical practice. It can be integrated more easily and comprehensively into the treatment process. It also creates opportunities for automated interpretation of the data in order to promote computer aided interaction between patient and ventilator. Thus, sEMG measurement offers a promising alternative to Pes measurement to prevent diaphragmatic atrophy and asynchrony events and thus lead to a reduction in mortality in mechanically ventilated patients.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Koch, Willi Meinrad
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 4Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- ger
Identifiers
dc:identifier.*- Identifier URI
- https://refubium.fu-berlin.de/handle/fub188/46788