Effect of Patient-related Variables on the Alarm Rate of Intensive Care Units’ Monitoring Devices and Prediction of the Alarm Rate Using Machine Learning Models

Abstract

dc:description.abstract

Intensive care units (ICUs) have been overflowed with alarms from monitoring devices for decades. Most of these alarms are either false-positive or require no clinical intervention. This can lead to alarm fatigue, which is a desensitization towards monitoring alarms. Alarm fatigue can cause burnout of caregivers, prolonged length of stay or in severe cases even death of patients. Although many solutions to this problem have been explored, none of them has been implemented in clinical routine to date. The aim of this study was to identify patient characteristics that influence the alarm rate in the ICU, especially characteristics related to high alarm rates, and to predict the alarm rate of patients. Alarm logs from monitoring devices in eight ICUs were extracted between September 2019 and March 2021 and linked with extracted patient characteristics from electronic health records (i.e., patient demographics, stay characteristics, clinical scores and diagnoses). Technical alarms, patients that were either less than 18 years of age or had less than 24 hours of alarm data, were excluded. The alarm rate per patient per day was calculated and categorized in a high and low alarm rate compared to the median. Then a logistic regression as well as a random forest model and logistic regression model were performed. The logistic regression showed that invasive blood pressure monitoring (OR 4.68, 95%CI 4.15-5.29, p<0.001), invasive mechanical ventilation (OR 1.24, 95%CI 1.16-1.32, p<0.001), heart failure (OR 1.26, 95%CI 1.19-1.35, p<0.001), chronic renal failure (OR 1.18, 95%CI 1.10-1.27, p<0.001), hypertension (OR 1.19, 95%CI 1.13-1.26, p<0.001), a high Richmond Agitation Sedation Scale (OR 1.22, 95%CI 1.18-1.25, p<0.001) and scheduled surgical admissions (OR 1.22, 95%CI 1.13-1.32, p<0.001) were significantly associated with a high alarm rate. The random forest model performed slightly better with an area under the receiver operating characteristic (AUROC) curve of 0.67 in comparison to 0.65 for the logistic regression model in predicting the alarm rate of patients. Based on the results of this study, alarm management should be intensified for patients with the above-mentioned characteristics, since they are more likely to have higher alarm rates. This could be a step towards delivering better care and achieving better conditions for both patients and staff in the ICU.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sinno, Zeena-Carola
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 3

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sinno, Zeena-Carola. Effect of Patient-related Variables on the Alarm Rate of Intensive Care Units’ Monitoring Devices and Prediction of the Alarm Rate Using Machine Learning Models. 2025. https://doi.org/10.17169/refubium-46913