Back to search

Freie Universität Berlin

Comparison of patient-specific fixation devices and -materials in one segmental mandibular reconstruction using a finite element analysis

Abstract

dc:description.abstract

Mandibular reconstruction represents a clinical challenge. One of the major complications is osseous non-union of the residual mandible and the donor bony segments (mostly fibula). In the last years, patient-specific titanium reconstruction plates are increasingly used since these pre-planned and anatomically customized plates simplify and shorten the surgery. However, the large reconstruction plates further increase the rates of osseous non-union. Therefore, alternative fixation strategies such as the use of smaller plates (for example miniplates) and alternative materials (for example magnesium) are of interest. The present study aimed to evaluate the biomechanical conditions of a one segmental mandible reconstruction with a fibula free flap under various fixation scenarios including patient-specific reconstruction plates, miniplates and combinations of both. Furtherly, the materials titanium and magnesium were investigated. As a methodology, a finite element analysis of a one segmental mandibular reconstruction was chosen to investigate the intersegmental strains as the main stimulus for bone healing and the maximum in-plate stresses as predictors for material failure. The results show higher strains under titanium reconstruction plate fixation in the posterior area in comparison to the anterior area and higher strains in the anterior area compared to the posterior area under titanium miniplate fixation. When combining a posterior short titanium reconstruction plate and anterior titanium miniplates, these effects could be partially combined. The use of magnesium locally increased the strains. The in-plate stresses were observed to be lower under reconstruction plate fixation compared to miniplates, larger in the posterior areas compared to the anterior areas and the relative stresses (ratio of maximum stress to yield stress) were found to be larger in magnesium plates compared to titanium plates. Furthermore, two plate-protective plate configurations were identified: • The use of a short posterior reconstruction plate reduced the stresses in the anterior plates compared to posterior miniplates • When two miniplates were paired in parallel, the titanium plate acted as load-bearing and, thus, plate-protective for the magnesium plate A previous study found a significantly better bone healing outcome in the posterior area than in the anterior area under reconstruction plate fixation, suspecting biomechanical reasons. In the present study, this observation could be correlated to the varying mechanical strains in the healing regions. Since miniplates and magnesium increase the anterior strains, the anterior application of these fixators could increase the rates of osseous union. To conclude, a combination of varying materials and patient-specific plate designs might be beneficial for bone healing. The anterior areas were identified as potential application areas for magnesium miniplates.

Degree

thesis:*
Department dc:contributor.department
Charité - Universitätsmedizin Berlin
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ruf, Philipp
Committee member dc:contributor.committeemember
  • N.N.

Subjects

dc:subject × 6

Rights

dc:rights.accessrights
Statement dc:rights.accessrights
  • open access
Language dc:language
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Freie Universität Berlin
Base URL
refubium.fu-berlin.de/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ruf, Philipp. Comparison of patient-specific fixation devices and -materials in one segmental mandibular reconstruction using a finite element analysis. 2025. https://doi.org/10.17169/refubium-48065